Installation Instruction
17
WARNING
If no optional operation lock device is installed, make sure the KEY input is short circuited with the COM input. Otherwise
the equipment cannot be started.
If no safe close device is installed, make sure the SAFE CLOSE input is short circuited with the COM input. Otherwise the
equipment cannot be started.
Position wings ~20 cm from total closure. Turn the power switch to 1 to power the equipment.
The automatism resets limits to reduced speed first completely opening and then closing.
Multi-logic selector not installed:
when the equipment finishes limit reset it is ready to work in 2 RADAR logic.
Multi-logic selector installed:
when the equipment finishes limit reset it is ready to work and is positioned in the
“STOP CLOSED” logic.
At the end of reset the equipment is ready for use; check correct sensor operations for opening command and safety con-
trol.Also check anti-crushing sensitivity; if the value requires increasing and decreasing, see the advanced selector manual.
To test automatism operations without connections to the open command device use the START button on the unit (see
Fig.
17
)
Start Up