Light Millennium 

‰

 

Telescopica Millennium 

‰

 

Pratika Millennium

 

 

 

‰

 

Maintenance Operation 

‰

 

Intervention by Request

 

 

During a scheduled maintenance operation, carried out by an authorised technician, it is advisable to 
carefully perform the checks and procedures listed below : 

 

‰

 

Remove the mains power supply using the bipolar switch upstream from the automatism. 

 

‰

 

Open the automatism by removing the cover. 

 

‰

 

Disconnect the batteries. 

 

‰

 

Check the tightening of the screws on the carriages and the components installed inside the box. 

 

‰

 

Check the connections of the wiring between the accessories, sensors and the electronic control unit. 

 

‰

 

Clean the runway with a cloth (without detergents) and check that it is intact.  

 

‰

 

Check the smoothness of the frame, its general conditions (evaluate any misalignments caused by 
impacts) and check, above all, that there is a minimum space of 5 mm between the pavement and the 
wing so as to guarantee correct sliding even in the event of extensive thermal expansions of the frame. 

  

‰

 

Clean the pulleys of the carriages and check the wear; replace if necessary. 

 

‰

 

Grease the runway with a thin layer of bearing grease. 

 

‰

 

Check the wear of the belt and grease it. 

 

‰

 

Reconnect the automatism to the mains power supply and the batteries. 

 

‰

 

Check the wear and correct operation of the floor guide; grease or replace it if necessary. 

 

‰

 

Check the wear of the rubber stops; replace and adjust them as necessary. 

 

‰

 

Check the correct operation of the blocking device, manual release and automatic reset. 

 

‰

 

Check the safety sensors (functionality and adjustment). 

 

‰

 

Check the detection sensors (functionality and adjustment). 

 

‰

 

Check the movement of the wings during braking and approach. 

 

‰

 

Verify the correct selection of the operation logics. 

 

‰

 

Check the efficiency of the batteries by operating the installation for a period without the mains power 

supply. 

 

‰

 

Test the correct operation of the antipanic breakaway system, if installed.

 

 
 
 