![SES SE-2040-3 User Manual Download Page 8](http://html1.mh-extra.com/html/ses/se-2040-3/se-2040-3_user-manual_1247137008.webp)
SEALED ENERGY SYSTEMS
®
8
User Manual
3.1.5. Charge 0ºC to 45ºC
Charge Temperature Limits: As Shown below,
≤
80%RH
The battery shall be capable of continuous charge at 12.6V,
as shown in the graph below. A dedicated level II or level III
smart battery charger is required to charge the battery.
Using this type of charger, the battery will request
appropriate charging Voltage and Current from the smart
battery charger.
The FULLY_CHARGED bit in the BatteryStatus() will be set
when the charging current tapers down under 200mA while
charging at 12.6V.