The  battery  pack  comprises  the  individual  elements  as  shown 
below: 

 
 
 
 
 

 
 
 
 
 
 
 
 

 

2.3 

General Precaution 

 

2.3.1  Handling 

 

 

Avoid shorting the battery. Do not immerse in water. 

 

Do not disassemble or deform the battery 

 

Do not expose to, or dispose of the battery in fire. 

 

Avoid excessive physical shock or vibration. 

 

Keep out of the reach of children. 

 

Avoid storage in direct sunlight. 

 

Do not short-circuit a battery. 

 

In the event of a battery leaking, do not allow the liquid to 
come  in  contact  with  the  skin  or  eyes.  If  contact  has  been 
made, wash the affected area with copious amounts of water 
and seek medical advice. Keep batteries clean and dry. 

 

Secondary batteries need to be charged before use. 

 

When  possible,  remove  the  battery  from  the  equipment 
when not in use. 

 

Do  not  store  batteries  longer  than  1  month  in  discharged 
state.  Do  not  storage  batteries  longer  than  1  year  without 
recharge. 

 

2.3.2  Charge & Discharge 

 

 

Battery must be charged in appropriate charger only. 

 

Never use a modified or damaged charger. 

 

Specified product use only. 

 

Operating Temperature  

 

For Charge: 0

O

C to +45

O

 

For Discharge: -20

O

C to +55

O

 

2.3.3  Storage 

 

 

Store in a cool, dry and well-ventilated area. 

 

Storage Temperature: -20

O

C to +45

O

 

Recommender Storage Temperature 20

O

C + 5

O

 

Summary of Contents for SE-2040-2

Page 1: ...ery Model SE 2040 2 SE20402NR29 10 8V 5 7AH 61 56Wh Statement of Confidentiality The information contained within this document is confidential and proprietary to Sealed Energy Systems This informatio...

Page 2: ...ic Levels 12 3 3 3 SMBus Data Protocols 12 3 3 4 SMBus Host to Battery Message Protocol 13 3 3 5 SMBus Battery to Charger Message Protocol 14 3 3 6 SMBus Battery Critical Message Protocol 15 3 3 7 Hos...

Page 3: ...ical capacity of 2 85Ah giving a battery pack of 10 8V and 5 7Ah typical The battery is capable of communicating with host or the charger through the System Management Bus SMBus The battery is fully S...

Page 4: ...contact has been made wash the affected area with copious amounts of water and seek medical advice Keep batteries clean and dry Secondary batteries need to be charged before use When possible remove...

Page 5: ...with local state and federal laws and regulations Consult universal hazardous waste regulations for further information regarding disposal of spent batteries If the internal cells are leaking broken...

Page 6: ...Transport Regulations Expended Lithium Ion Battery packs are not considered hazardous waste Lithium ion battery packs that have been involved in a fire maybe considered hazardous waste and should be...

Page 7: ...w 80 RH The battery shall be capable of continuous discharge within the Operating Boundary as shown in the graph below Host devices should be designed for a controlled shutdown following battery notif...

Page 8: ...shown in the graph below A dedicated level II or level III smart battery charger is required to charge the battery Using this type of charger the battery will request appropriate charging Voltage and...

Page 9: ...sent on each pack for mechanical alignment adjacent to the positive terminal The SMBus Clock and data lines require separate pull ups to system logic voltage NOT the battery voltage Typically a 15K pu...

Page 10: ...n pack LED s with push button activation Charge control is used to provide optimal and safe charging requests to an SMBus level II or level III charger The system has three modes of operation normal s...

Page 11: ...e not taken into consideration 3 2 3 2 Temperature The internal pack temperature is measured by an NTC thermistor attached to the cell stack Temperature readings have a resolution of 0 1 K The absolut...

Page 12: ...ery Data Specification Rev1 1 Dec15 1998 Smart battery Charger Specification Rev1 0 June27 1996 3 3 2 SMBus Logic Levels SYMBOLS PARAMETERS LIMITS UNITS MIN MAX Vil Data Clock input low voltage 0 3 0...

Page 13: ...p condition Write Word Protocol Write Word Protocol w PEC SMBus Host Master Smart Battery Slave 3 3 4 2 Read Word Reading data is slightly more complex than writing data First the host must write a co...

Page 14: ...3 3 5 SMBus battery to Charger Message Protocol The Smart Battery acting as an SMBus master will dynamically alter the charger characteristics of the Smart Charger behaving as an SMBus slave using th...

Page 15: ...of the message and that the following 16 bits are its status Battery Critical Message Battery Critical Message w PEC SMBus Host Master Smart Battery Slave 3 3 7 Host to battery Message Slave Mode The...

Page 16: ...ack s internal temperature 0 1 oK r Function Command Code Description Unit Access Default POR Voltage 0x09 Returns the battery s voltage measured at the cell stack mV r Current 0x0a Returns the curren...

Page 17: ...Returns a character array containing the manufacture s name string r SES Device Name 0x21 Returns a character array that contains the battery s name string r SE 2040 2 Device Chemistry 0x22 Returns a...

Page 18: ...hreshold OTC recovery 56 C OTD recovery 65 C Bit Battery Status Set When Action When Set Cleared When 11 TERMINATE_DI SCHARGE_ALA RM Relative State of Charge 0 Cell Under Voltage CUV Over Current Disc...

Page 19: ...the secondary are non resettable 3 4 2 Charge Protection Over Voltage The primary protection circuit will prevent the battery from charging if any cell voltage 4300mV Then once all cell voltages are...

Page 20: ...settable rendering the battery pack non functional Over Current The primary protection circuit also provides continuous over current protection and will prevent the battery from discharging at Curren...

Page 21: ...nector The recommended interconnection mating male connector is AMP TE part no 5787428 1 or 5787421 1 3 6 3 Packing The batteries are packaged in bulk per current regulations 3 7 Environmental Safety...

Page 22: ...0 charge discharge cycles where the charge phase is CC CV C 3 12 6 0 05V and the discharge is C 3 down to 3 0V Cell at 25 C 3 8 2 Warranty Sealed Energy Systems maintains a high quality standard All p...

Page 23: ...rder to prevent parasitic drain on the battery the electronics will go into a shutdown mode if any cell voltage 2300mV If this should happen the battery pack will require an initial low charge to acti...

Page 24: ...SEALED ENERGY SYSTEMS 24 User Manual 4 0 Mechanical Drawing...