SerVision
Embedded Video Gateway System Guide
Configuring Camera Settings
100
Figure 107: Sensitivity level applied to selected rectangle
6. If you want to apply the current sensitivity level to individual regions, do one of the following:
With the
Change Multiple Times
checkbox
selected
, double-click the region.
With the
Change Multiple Times
checkbox
cleared
, click the region.
An
x
of the color representing the selected sensitivity level appears on the image (or the x is removed from the
area, if the current sensitivity level is "Motion Disabled").
7. Repeat steps 3–6 as necessary for each type of sensitivity level you want to apply to a region of the FOV.
Figure 108: Region sensitivities set
8. Under
Debounce
, specify the minimum interval between events, in seconds. Range: 3–30 seconds. If motion
is detected, and then ceases, the motion detection event is only closed if this amount of time has passed
without any motion.
Example:
Motion is detected at 3:15:05 and continues until 3:15:45. After this, motion is not detected again
until 3:16:10, 25 seconds after it was last detected. If the debounce interval is 15 seconds, two separate VMD
events are triggered. If, on the other hand, the debounce interval is 30 seconds, only one VMD event is
triggered, beginning at 3:15:05 and continuing past 3:16:10.
Tip:
If a lot of motion is likely to be detected by the camera, it is best to specify a relatively long debounce
interval, so that the system does not generate a very long list of short events.