HEAT CONTROL (1):
This dial controls the water temperature. Turn it clockwise to increase
water temperature and counterclockwise to decrease temperature.
The heater will operate only if the circuit locator light (#5) or the bypass
switch (#6) is on.
HEAT MODE LIGHT (2):
This light will only illuminate when the heater is heating and will turn off
when it reaches operating temperature. During normal operation, the
“MODE” light will be on most of the time.
PUMP CONTROL (3):
This dial controls motor speed and pump pressure. Adjust the dial
clockwise to increase pressure and counterclockwise to decrease
pressure or turn off pump. The pump runs off of cord #1. The pump
spraying pressure will be observable at the pressure gauge.
VACUUM SWITCH (4):
This switch will illuminate when the vacuum motors are on. The
vacuum motors run off of cord #1.
CIRCUIT LOCATOR (5):
When this light is on, it indicates that cord #2 (Identi
fi
ed by the red “H”
on the back of the extractor.) is on a separate line from cord #1. Cord
#2 supplies voltage to the heater allowing it to heat to the temperature
range indicated by the Heat Control dial (#1) on the switch plate.
BYPASS SWITCH (6):
The bypass switch will illuminate when it is activated and will completely
bypass the circuit locator system. Use this system only when the circuit
locator light will not turn on and you know each cord is on a separate
circuit.
CAUTION:
THE CIRCUIT BREAKER IN THE WALL PANEL CAN TRIP IF
BOTH CORDS ARE ON THE SAME CIRCUIT AND THE BYPASS (heat)
SWITCH IS TURNED ON.
NEVER LET YOUR MACHINE OR YOUR WAND FREEZE
SOLUS-500
SWITCH PLATE
1
3
4
6
2
5