1. FUNCTION

D3590-A

2

-201

PAGE

 

2

SERVI GROUP

[email protected]

www.servicatalogue.com

Servi PRC NOISEKILLER reactive pulsation dampener eliminates the eff ects from damaging pulsations and vibrations 

in hydraulic systems. Pump pulsations cause noise, which is a serious environment problem in most vessels and many 

facilities. 

In addition, pump pulsations cause damage in the form of wear on the hydraulic system components and sealing 

systems. Servi PRC pulsation damper greatly reduces noise and prolongs the service life of the components in the 

hydraulic system. 

The Servi PRC is suitable for pump frequencies of 100Hz and above, and since it has no pre-charge or cushioning 

element, it does not require any maintenance. 

2. TYPICAL AREAS OF USE

The Servi PRC has shown to have the best sound reduction eff ect on vessels (ships and rigs) with hydraulics working 

continuously or at least most of the time. The typical hydraulic whine spread through the metal construction in decks 

and bulkheads will be greatly reduced.

The Servi PRC range of Noisekillers have been developed to fi t most hydraulic systems, old or new and can be installed 

in any orientation.

The Noisekiller must be installed on the pressure side of the pump. A hose is recommended between the pump and 

the Noisekiller. If this is impossible, due to the size of the hose, the Noisekiller can be connected directly to the pump. If 

this is the case, it is very important that the Servi PRC is installed on the same fl exible mounting as the pump.

The full fl ow of the pump must go through the Noisekiller in the fl ow direction of the arrow on the unit. The fl uid can fl ow 

both ways, but the damping eff ect is best in the main direction.

To calculate the correct, maximum distance from pump to PRC, use the following formula:

160/pump frequency = distance in meters

Example: 

7 piston pumps, 1450 RPM, = 7*1450/60 = 169 Hz

160/169 = 0,94 meter 

If the Noisekiller is further away, the result may be reduced 

or no damping, due to parallel oscillation.