Server Serve Better CP-RP Manual Download Page 4

Page 4

• Fully rinsing and drying all parts can help  
  prevent corrosion. Elements and minerals in  
  tap water can accumulate on stainless steel  
  parts and create corrosion.
• Do not use abrasive, caustic or ammonia  
  based cleansers.
• Do not use products containing acids,    
  alkalines, chlorine, or salt. These agents can  
  corrode stainless steel.
• Do not use metal scrapers or cleaning pads  
  that could scratch surfaces.

• A mildly abrasive nylon or brass brush may  
  be used to remove any stubborn deposits.

This durable pump includes 

stainless steel components.

 

If you notice corrosion beginning on any 
stainless steel surface, you may need to 
change the cleansing agent, sanitizing agent, 
or the cleaning procedures you are using.

CARE OF STAINLESS STEEL

CLEAN-IN-PLACE

 

PROCEDURE FOR PUMPS

RINSE

• Place lower end of pump into 2 cups  
  (.5 L) of hot tap water (approximately  

 

  110°F /43°C) and pump until all tap  

 

  water is expelled.

2

RINSE

• Place lower end of pump into 1 cup 
  (.24 L) of hot tap water (approximately    
  110°F /43°C) and pump until all tap  

 

  water is expelled.

4

SANITIZE

• Mix one 1 oz (30 mL) packet of KAY-5  
  Sanitizer/Cleaner (EPA REG No. 5389- 

 

  15) with 2.5 gallons (9.5 L) of tap water    
  (approximately room temperature).
• Place lower end of pump into this  

 

  sanitizing mixture and repeatedly operate  
  pump until 1 quart (.95 L) sanitizing  

 

  mixture is pumped through pump.

3

CLEAN

• Pump out all (if any) remaining food  

 

  product from inside pump body.
• Wash and rinse off outside of pump body.
• Flush out and rinse inside of pump.
• Place lower end of pump into container    
  full of water and operate pump until all (if   
  any) remaining product is expelled  
  and only warm water flows from discharge  
 tube. 
• Mix 1 tsp (5 mL) of dishwashing detergent  
  with 1 quart (.95 L) of hot tap water  

 

  (approximately 110°F /43°C).
• Place lower end of pump into cleaning    
  mixture. Pump until all cleaning mixture  
  is expelled.

1

Summary of Contents for Serve Better CP-RP

Page 1: ...sing systems MODEL CP RP for purchasing our Stainless Steel Pump This quality NSF listed pump delivers precise portions and lasts for years of service CONSISTENT PORTIONS SERVE BETTER Thank You Your p...

Page 2: ...ELIVERS 1 FL OZ PORTIONS SPRING 82016 FOOD EQUIPMENT LUBRICANT 40179 BRUSH 82526 BRUSH 82049 COLLAR S USED PORTION RESULT None 1 fl oz 1 Sm 7 8 fl oz 1 Lg 3 4 fl oz 1 Lg 1 Sm 5 8 fl oz 2 Lg 1 2 fl oz...

Page 3: ...SF International lists this pump as Not acceptable for dispensing potentially hazardous foods PUMP CLEANING Use dishwashing soap hot water and nylon brush YES Pump is dishwasher safe FLUSH RINSE all p...

Page 4: ...hot tap water approximately 110 F 43 C and pump until all tap water is expelled 2 RINSE Place lower end of pump into 1 cup 24 L of hot tap water approximately 110 F 43 C and pump until all tap water...

Page 5: ...nse and flush pump See PUMP CLEANING on page 3 REMOVE LOCKING COLLAR REMOVE GAGING COLLAR S if used REMOVE HEAD INSERT from inside head tube REMOVE SPRING WASHER from piston REMOVE SEAL ASSEMBLY from...

Page 6: ...e 3 SLIDE HEAD INSERT beveled edge first into head tube TIP The end with smaller hole should go in first SLIDE LOCKING COLLAR wide side down towards flared end of head tube INSERT PISTON ASSEMBLY into...

Page 7: ...valve body Rotate discharge tube clockwise and press down firmly to secure into slots on valve body 8 SECURE LID Slide discharge tube nut onto discharge tube Rotate nut clockwise to secure 10 INSTALL...

Page 8: ...repair or return contact Server Products customer service to request a Return Authorization Number Merchandise must be sent to Server Products with this number Service is extremely prompt Typically un...

Reviews: