Control Functions: 
 

 

 

POWER BUTTON 

Touch to 

START

 or 

STOP

 the heater.

 

 
SPEED INDICATOR 

To control the fan speed touch the SPEED button 
repeatedly until the desired fan speed is selected 

FAN ONLY INDICATOR 

To set the heater to Fan Only setting, press the 
FAN symbol until the Green ‘Fan Only’ indicator is lit.

 

FREEZE GUARD INDICATOR  

When the heater is set to the Freeze Guard setting, it will 
switch on if the temperature detected by the electronic 
controller falls below 5°C. To set the heater to Freeze 
Guard setting, Press the ‘freeze symbol’ on the left side of the 
control panel until the Red Freeze Guard indicator is lit

 

SELECTOR 

-

  BUTTON 

 

Touch to

 DECRESE 

the temperature setting.

 

SELECTOR 

+

 BUTTON

 

Touch to

 INCREASE

 the temperature setting.

 

TAMPER LOCK BUTTON 

Activating the Tamper Lock button will ensure that the 
temperature setting cannot be changed, yet the heater is 
still able to be turned on or off.

 

To activate the Tamper Lock,  hold down the button for 
approximately 3 seconds, until you hear a beep and the  
Tamper Lock red indicator is lit.

 

To deactivate this function, repeat the operation. 

Summary of Contents for Optima S2055

Page 1: ...1 S2055 6 Wall Mount Space Heater with Cooling Fan Installation and Operating Manual Optima...

Page 2: ...ree performance it is recommended that on a regular basis the unit be isolated from the power supply and a vacuum cleaner used to remove dust and fluff from the inlet and outlet grilles Do NOT allow t...

Page 3: ...h POWER on the control panel and the adjacent blue LED will light SETTING THE HEAT CONTROL THERMOSTAT To set the electronic thermostat at the required setting press the selector buttons as follows To...

Page 4: ...second the and controls A blue indicator will begin flashing The 3 hour countdown timer is now set and after 3 hours the heater will turn OFF automatically 3 FAN ONLY MODE Optima has a very powerful...

Page 5: ...controller falls below 5 C To set the heater to Freeze Guard setting Press the freeze symbol on the left side of the control panel until the Red Freeze Guard indicator is lit 5 SELECTOR BUTTON Touch...

Page 6: ...ched by a person in the bath or shower The minimum required distance from the heater to any floor is 150mm The minimum required distance from the heater to any adjacent wall is 200mm The heater MUST b...

Page 7: ...ter against the wall and locate the mounting screws ensuring that the heater is level and the minimum distance between the heater and the adjacent surfaces are adhered to 3 Pull the heater gently down...

Page 8: ...imer is now set and after 3 hours the heater will turn OFF automatically 4 Press the POWER button and the heater will operate Safety Cutout Your Serene Wall Fan Heater is fitted with an auto reset the...

Page 9: ...d outlet grilles Ensure the heater is dry before turning the mains power supply to the heater back on Specifications Style Surface Mounted Model S 2055 S 2066 Height 272mm 272mm Width 525mm 590mm Dept...

Page 10: ...ristchurch 8024 AUSTRALIA e auenquiry serene ind com w www serene ind com HONG KONG t 852 2325 3210 f 852 2325 3166 e info serene ind com w www serene ind com 1010 10th Floor Block A Alexander Industr...

Page 11: ......