Data Pro
P/N 10029355 Rev AE
Operation Manual
Page 51 of 92
Once the USB flash drive is in the USB port, allow approximately 30 seconds for the Data Pro
application to detect its presence. Do not remove the USB memory from the port until the update is
complete. Removing the USB memory from the port may damage the operating system. The execution
of
‘Firmware Update’
happens automatically, in the following steps,
without
input from the
user/operator:
Closes the current running program
Updates the Data Pro application
Reopens the updated application
Figure 49
– Firmware Update and FW Version Check
Once the updated application begins, check the
‘
Data Pro
FW Version’
by going to Menu
About to
make sure that
‘FW Version’
matches the intended USB firmware update version (
).
8.7.5
Sample Rate
To change the gauge sample rate go to Main Menu
System
Sample Rate.
The sample rate affects the following parameters:
Refresh rate of gauge data on the front screen.
Data written to the *.csv files and exported to the USB drive.
Refresh rate of gauge data in Relay
’s ‘Last Reading’ column under ‘Peripheral Configuration’.
Refresh rate of gauge data in
‘4mA’ and ‘20mA’ cells under ‘Peripheral Configuration’.
The unit for the sample rate is
‘
seconds
’.
As an example, to set aa 15-minute sample rate, enter a
sample rate of 900 seconds (15x60).
8.7.6
Restart
To restart the Data Pro application, execute the following steps:
Menu
System
Restart
This action closes the running program, re-opens the application, then restarts the process of scanning
for connected gauges. It uses the previously saved configuration setting and resumes writing to the
previously created gauge data files.