Technical Data:

Height:

50.8 cm (20 in.)

Width:

16.6 cm (6.5 in.)

Depth:

18.6 cm (7.3 in.)

Volume:

approx. 3.3 l (0.8 US gal.)

Pump:

NP 1600
220 – 240 V ~ 50 Hz, 20 W
max. 40°C (104°F)

Hmax:

1.2 m (3.9 ft.)

Qmax:

1,400 l/h (369 US gal./h)

IPX8:

up to 1 m (3.3 ft.) water depth

Troubleshooting:

Spare parts:

Rotor with pinwheel
Ceramic shaft with rubber bearings
Pump NP 1600 (complete)
Flotate cup with cover
O-ring seal for outlet 

Disposal of the unit:

Waste electrical and electronic equipment (WEEE)
must not get into domestic waste!
If ever the unit cannot be used anymore, the consumer
is legally obliged to hand in waste electrical and elec-
tronic equipment (WEEE) separately from domestic
waste
, e.g. at a collection point of his community/his
district. This ensures that waste electrical and elec-
tronic equipment (WEEE) is expertly processed and
that negative effects to the environment are avoided.

Therefore electrical and electronic 
equipment bears the following symbol: 

Warranty:

When following the directions for use, the sera marin
Protein Skimmer 600 S 
will perform reliably. We are lia-
ble for the freedom from faults of our products only
within legal regulations beginning with the purchase
date.
We  are liable for complete flawlessness at delivery.
Should usual wear and tear occur by use as intended
by us, this is not considered a defect. Warranty claims
are also excluded in this case. This particularly refers to
the running unit (rotor, shaft, rubber bearings) and the
hoses.
In every case of a defect we recommend that you con-
sult the specialized retailer where you purchased the
unit. He will be able to judge whether it is actually a
warranty case. In case of sending the unit to us we will
unnecessarily have to charge you for occurring costs.
Any liability because of contract breach is limited to
intent or gross negligence. sera will be liable in case of
slight negligence only in case of injuries to life, body
and health, in case of essential contractual obligations
and with binding liability according to the product lia-
bility code. In that case, the extent of liability is limited
to the replacement of contractually typically foreseea-
ble damages.

Problem

Possible cause

Troubleshooting

Insufficient air intake rate

Intake valve (4.19) insufficiently o-
pened

Open intake valve (4.19) further

Air hose (4.17) is encrusted with
lime or dirty

Clean

Intake nozzle (4.16) on the pump is
dirty

Pull off and clean

Pump performance is too low

Clean rotor and shaft

Foam too moist/
too much foam

Water level within the unit is too
high

Open flow adjustor (4.4) further

Too much air

Close intake valve (4.19) further, 
first try to adjust with the flow
adjustor (4.4) 

Foam too dry/
very viscous foam

Water level within the unit is too
low 

Slightly reduce flow rate at the flow
adjustor (4.4)

Insufficient pump performance

Clean rotor, shaft and intake nozzle

Insufficient foam formation

Insufficient amount of air

Open intake valve (4.19) further

Foam formation too strong, very
brownish flotate, very sticky foam

Water strongly polluted

Partial water change, feed less

see: Insufficient foam formation

Increase flotate moisture

Foam formation breaks down

Feeding fatty food (fish, mussels)

Foam formation will begin again
after a few hours

Air intake congested 

Clean air intake or open further

1 m

(3.3 ft.)

Reviews: