airPUMP
AP025
(plastic)
www.sera-web.com
5
WARNING
Do not exceed minimum and maximum temperature limits of pump components.
A table of temperature limits is provided in the “Pump Data” section of the manual.
WARNING
Do not exceed maximum pressure stated on the pump serial number sticker.
WARNING
Prior to operating, check pump for any worn o-rings, gaskets, or seals. Any leaking or damaged o-rings, gaskets, or seals
must be repaired or replaced immediately.
WARNING
Pump exhaust may be loud and contain particles. Wear appropriate ear and eye protection. In the event of a diaphragm
rupture material can be forced out of the air exhaust muffler. If product is hazardous or toxic, pipe exhaust to appropriate
safe area.
WARNING
Pump must be cleaned on a regular basis to avoid dust buildup greater than 5mm.
WARNING
The surface temperature of the pump depends upon the temperature of the fluid that is being pumped. The chart below
lists different fluid temperatures and the corresponding pump surface temperatures, which determine the Temperature Class
when used in a hazardous area.
Fluid Temperature
Maximum Surface
Temperature
Temperature
Class
Maxium Allowable
Surface Temperature
80°C (176°F)
80°C (176°F)
T6
85°C (185°F)