3 Command Line Reference
3.2.11
Station Settings
smp
gmp
setMarkerParameters
getMarkerParameters
MarkerName (60)
MarkerNumber (20)MarkerType (20)
StationCode (10)
MonumentIdx
ReceiverIdx
CountryCode (3)
SEPT
Unknown
Unknown
0 . . . 9
0 . . . 9
RxControl: Navigation > Receiver Setup > Station Settings
Use these commands to define/inquire the marker and station parameters.
The set of allowed characters for the
MarkerName
argument and for the
StationCode
argu-
ment is limited to:
_0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
The
StationCode
argument is the site code associated to the station (typically four characters).
MonumentIdx
can be used to identify the monument when there are multiple monuments at
the same station.
ReceiverIdx
can be used to identify the receiver when there are multiple
receivers at the same monument. A three-letter ISO country code can be specified with the
CountryCode
argument.
If internal logging is enabled in one of the
IGS
file naming modes, the file name depends on
the settings of the
command. Refer to the description of the log-
ging commands (
) for details.
The parameters set by this command are copied into the
SBF block, which
defines the file name and the header contents when converting SBF files into RINEX with the
sbf2rin
program.
Example
COM1>
smp, Test, 356, GEODETIC, TST1, 0, 0, BEL<CR>
$R: smp, Test, 356, GEODETIC, TST1, 0, 0, BEL
MarkerParameters, Test, 356, GEODETIC, TST1, 0, 0, BEL
COM1>
175
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...