4.3. US
I
NG PPP CORRECT
I
ON DATA W
I
TH THE POLARX5
Step 3: Select PPP positioning mode
Positioning modes can be selected on the
‘
Position
’
window as shown in Figure 4-15. Select
‘
Rover
’
and make sure that
PPP
is also selected as a positioning mode.
Figure 4-15:
Con
fi
gure the PolaRx5 as a rover and enable PPP positioning mode
Step 4: Beam selection
You can choose the L-Band beam selection mode by clicking
‘
Settings
’
in the SECORX
con
fi
guration window as Figure 4-16 shows.
I
n the default
auto
mode, the demodulator will try to lock on to a visible beam, preferring
beams to which access has been granted.
I
n
manual
mode, you can select the beam you want to track from the
‘
Manual beam
selection
’
drop-down list. The details of two additional beams can also be entered and saved
in the
‘
Advanced Settings
’ fi
eld. A beam is characterized by a frequency and data rate.
Figure 4-16:
Selecting
‘
auto
’
mode for beam selection
30