6.3. HOW TO LOG DATA FOR PROBLEM DIAGNOSIS
6.3 How to log data for problem diagnosis
If the AsteRx-U MARINE Fg does not behave as expected and you need to contact Septentrio
Support Department, it is often useful to send a short SBF data
fi
le that captures the
anomalous behaviour, as well as a Diagnostic Report from the receiver.
6.3.1 Support SBF
fi
le
Step 1: Log the Support SBF data blocks
On the
Logging
page, click on
New SBF stream
. In the next window, you can select the
SBF blocks you wish to log. By selecting
Support
as shown in Figure 6-8 the most useful SBF
blocks for problem diagnosis will be automatically selected. Click
OK
then turn
on
logging.
Again click
OK
to start data logging.
Figure 6-8:
Click on
New SBF stream
and select
Support
Please note that logging the
Support
data blocks requires a large throughput of data that
may not be compatible with other CPU-intensive tasks such as data output at higher rates.
68