Toilet placement

Separett Tiny has no requirements for room temperature and works in both cold and warm spaces. The only

requirements are that you must be able to lead the urine away and fit a ventilation pipe.

The toilet is made to be placed on the floor against the wall,and for extra stability it should be attached either

to the floor, wall or both.

Make holes according to installation template

The enclosed installation template shows possible installation options for urine drains and ventilation pipes

through the wall behind the toilet or through the floor. These options enable an installation without visible

pipes.

Install ventilation pipe

The toiletis designed for 50 mm pipes (outer diameter). For optimal function it is recommended that you use

Separett’s own installation kitthat has pipes and angles in the correct dimensions.

Separett Tiny can be installed with up to 5 meters of ventilation piping and 2 90-degree bends. Ventilated air

can go through a wall, floor or roof, for example, up into an attic and out through a suitable side of the house.

If there is already a ventilation pipe present from a previous toilet installation, the toilet may be connected to

that duct, provided that it is not smaller than 50 mm and that it meets the pipingrequirements. Should you

need longer piping that exceeds the recommendations above, you may install an extra fan (art. no.: 13008)

The toilet comes with a coupling for connecting the included 40 cm-long 50 mm pipe to a 1.5 inch pipe (sche-

dule 40). For more information on this, please read section X.

X. When connecting the toilet to 1.5 inch pipes

Ensure as short and simple a piping as possible, as the inner diameter of these

pipes is smaller than the pipes in the Separettventilation kit, hence the air-

flow restrictions. For these installations, a maximum of 4 meters of pipe and 2

90-degree bend is recommended.

This toilet is designed for direct connection with 50 mm pipes. A coupling to

connect the toiletto a 1.5 inch pipe (schedule 40) is also included. The inclu-

ded 50 mm pipe is to be connected to the toilet or to the supplied 90-degree

bend. The 50 mm pipe should be cut to a suitable length. Use a coupling to

continue the installation with 1.5 inch pipes (schedule 40).

1.5 inch pipes (schedule 40) have a smaller inner diameter and when using

these pipes, as short and simple installation as possible is desirable to ensure

high functionality. The total length of the pipes must be less than 4 meters

and a maximum of 2 x 90-degree bends is recommended.

Summary of Contents for 1271-01

Page 1: ...Tiny with urine tube art no 1271 01 Installation Manual Tiny 12356 01...

Page 2: ...hat rules apply in your munici pality Alwaysfollow local regulations Please view our installation video at www ecoflo com au To make sure the toiletstays odour free the fan in the toiletshould always...

Page 3: ...1 x Lid for solid waste container 1 x Adaptor ventilation pipe 50 mm to 1 5 schedule 40 1 x Basket for bioblock 1 x Pipe cap with insect net 50 mm 1 5 1 x Ventilation cowl 50 mm 1 5 2 x Screw for vent...

Page 4: ...stallation template 3 Install ventilation pipe 4 Install urine hose 5 Install ventilation pipe cap or ventilation cowl 6 Power supply for toilet 7 Connect the toilet to the ventilation pipe and urine...

Page 5: ...oilet may be connected to that duct provided that it is not smaller than 50 mm and that it meets the pipingrequirements Should you need longer piping that exceeds the recommendations above you may ins...

Page 6: ...gh to reach through an outer wall If additional pipes are needed to direct the air out of the house the Separett ventilation kit art no 1344 is recommended for Tiny It includes 4 meters of piping and...

Page 7: ...the recommendations for the installation of ventilation pipes If additional pipes are needed to direct the air out of the house the Separett ventilation kit art no 1344 is recommended for Tiny It inc...

Page 8: ...e risk of pests causing damage to the tube If you are goingto run the urine a longer distance than the 2 meters 6 6 ft of the supplied hose you should switch to a pipe after the 2 meters 6 6 ft Since...

Page 9: ...e toilet is to be installed against the wall the urine hose must be led through the side of the toilet which requires a hole to be made in the plastic For optimal results use the same drill you would...

Page 10: ...pipe cap or ventilation cowl It is important to ensure that the end of the ventilation pipe is protected from rain and snow and prevents insects from entering the toilet To achieve this the toiletcome...

Page 11: ...hen mounted as pipe ends in the same way as shown in previous sections It is also possible to use the ventilation cowl at a horizontal pipe end in more demanding conditions to ensure better protection...

Page 12: ...The toiletmust be connected to a power source The toiletcomes with a power adapter for 110 240 V and a 12 V batterycable Regardless of the power source the chord must be connected to the back of the t...

Page 13: ...is to be connected Tiny is designed to be fixed to the floor or to the wall For maximum stability both options can be combined Floor To attach the toiletto the floor use the supp lied screw or other s...

Page 14: ...er is not pre installed but must be installed on site as shown below The filtershould be cleaned regularly to maintain its proper functioning To install the yellow fan filter in the toilet follow the...

Page 15: ...Proudly distributed by ecoflowm 1300 138 182 info ecoflo com au www ecoflo com au 07 3889 6144...

Reviews: