Default Settings for Record, Camera, Record 2, and Timer
G Sensor Settings
Each bus yard or transportation facility has different requirements for G Sensor sensitivity settings. Seon
has found the following settings work in most cases:
• X – Forward/Back axis, set to +2/-2 and associate with an alarm.
• Y – Left/Right axis, set to +2/-2 and associate with an alarm.
• Z – Vertical axis, set to 0/0 and do not associate with an alarm.
These settings can be adjusted to fit specific requirements. The lower the settings, the higher the chances
are of generating false alarms.
Table 4
Default Record Settings
Record Settings
Repeat Record
On
Record Delay-On Time
30 sec.
Record Delay-Off Time
15 sec.
Power Delay-Off Time
15 sec.
Emergency Backup Power
Off
Alarm Partition Size
Off
Overwrite Alarm Partition
Off
Watermarking
Off
Table 5
Default Camera Settings (per camera row)
Camera Settings (per camera row)
Speed
15 FPS
Resolution
720x480
Quality
3
Audio
On
Table 6
Default Record 2 Settings (per camera row)
Record 2 Settings (per camera row)
Speed
5
Quality
3
Resolution
360x240
Table 7
Default Timer Settings
Timer Settings
Enable Timers: (per timer row)
Off
Day
WDY
Start
12:00 AM
End
12:00 AM
Set