SolaSmart™ Plus Installation Guide
Version 1.1 – Mar 2012
Page 19
B
IO
S
AFE
,
R
EHEAT
,
AND
B
OOST
F
UNCTIONS
,
C
ONTINUED
Reheat Mode
Either the Tank (Upper Tank) or Inlet (Lower Tank) Sensor and either the
Upper or Lower Element will be used in Reheat Mode. The Tariff Table on
page 5 specifies which sensor will be used for control and which element will
be used heating the tank. This enables the user to control the amount of hot
water stored in his tank based on electricity price fluctuations during the day.
Reheat Upper
Reheat Upper is the temperature that the element will stop heating the tank
in the Reheat Mode.
Reheat Lower
Reheat Lower is the temperature that the element will start heating the tank
in the Reheat Mode.
Boost
Pressing the HWC button should heat from the lower element until the Inlet
(Lower Tank) sensor reaches Reheat Max setting; for mid element tanks; this
will use upper sensor (as for all heating control with mid elements).
To stop Boost, press the HWC switch again.
Boost will only come on if the temperature is below Reheat Max and the
controller is not in BioSafe Mode.