Specifications
Specifications
Number of units that can be used
together
Connected units
1-5 units
Compressor stop/start frequency
Stop time
3 min or more
voltage fluctuation
within ±10% of rated voltage
Power source voltage
voltage drop during start
within ±15% of rated voltage
interval unbalance
within ±3% of rated voltage
10m(32.8ft)
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
15m(49ft)
15m(49ft)
Max.Height difference
SENA/18HF/MOZ
SENA/30HF/MOZ
Max. length for
all rooms
131 (40m)
197
(60m)
Max. length for
one indoor unit
82
(25m)
98
(30m)
Max. height different between
indoor and outdoor unit
49
(15m)
49
(15m)
Max. height different
between indoor units
SENA/36HF/MOZ
SENA/48HF/MOZ
262
(80m)
262
(80m)
115
(35m)
115
(35m)
49
(15m)
49
(15m)
When installing multiple indoor units with a single outdoor unit, ensure that the length of the
refrigerant pipe and the drop height between the indoor and outdoor units meet the requirements
illustrated in the following diagram:
Model
number
Unit: f
t
33 (10m)
33 (10m)
33 (10m)
33 (10m)