Senville RG51EU1 User Manual Download Page 4

4

TIMER DISPLAY Indicator: 

This display area shows the settings

of the TIMER. That is, if only the starting time of operation is set,
it will display the TIMER ON. If only the turning off time of operation
is set, it will display the TIMER OFF. If both operations are set,
it will show TIMER ON-OFF which indicates you have chosen 
to set both the starting time and off time.

6

FAN SPEED Indicator: 

Press the FAN SPEED button to select 

the desired fan speed setting (Auto-Low-Med-High). You selection
will be displayed in the LCD window except the Auto fan speed.

7

Operating  the Remote Controller

The Remote Controller uses two alkaline dry batteries

(LR03X2).

1. To install the batteries, slide the back cover of the battery
    compartment and install the batteries according the 
    direction (+and -)shown on the Remote Controller.
2. To replace the old batteries, use the same method as 
    mentioned above.

Install/Replace Batteries

NOTE:

 

All signs shown in the Fig.2  is for the purpose of clear

            presentation. But during the actual operation only the re-
            lative functional signs are shown on the display panel.

LOCK Indicator: 

LOCK display is displayed by pushing the 

LOCK button. Push the LOCK button to clear display.

OPERATION MODE Indicator: 

When press the MODE button, 

 it shows the current operating  mode --  AUTO

COOL

DRY

HEAT (Cooling only model  without)

 mode.

5

4

ON/OFF Indicator:

 This  symbol appears when the unit is turned 

on by the remote controller, and disappear when the unit is 
turned off.

3

NOTE

1. When replacing batteries, do not use old batteries or a different
    type battery.  This may cause the remote control to malfunction.
2. If  you do  not use  the  remote  controller  for  several  weeks
    remove the batteries. Otherwise battery leakage may damage
    the remote controller.
3. The  average  battery life  under normal use  is about 6 months.
4. Replace the batteries when there is no answering  beep from the
    indoor unit or if the Transmission Indicator light  fails to light.
5. Do not dispose batteries as unsorted municipal waste. Collection
    of such waste separately for special treatment is necessary.

5

Switch on the power and the OPERATION  indication lamp on the 
display panel of the indoor unit starts flashing, and turns off after 
flashes for 6 times.
1. Use the  MODE button to select AUTO.
2. Push  the TEMP button  to set  the desired  temperature within

O

O

    a range of 62 F ~ 86 F.
3. Push the ON/OFF button to start the air conditioner. The OPE-
    RATION lamp on the display panel of the indoor unit lights. The
    FAN SPEED is automatically set and there are no fan speed 
    indicators shown on the display panel of the remote controller.
4. Push the ON/OFF button again to  stop the  unit operation.

1. In the  AUTO mode, the air  conditioner  can  logically choose
    the mode of COOL, FAN and HEAT by sensing the difference 
     between the actual ambient room temperature and the set 
    temperature on the remote controller.
2. If the AUTO mode is not comfortable for you,  the desired 
    mode can be selected manually.

AUTOMATIC OPERATION

NOTE

1. If the AUTO mode is not comfortable, you may manually over-ride
   the settings by using  COOL, HEAT or FAN modes.
2. Push  the TEMP button  to set  the desired  temperature within

O

O

    a range of 62 F ~ 86 F.
3. Push the FAN SPEED to select the  FAN mode of  AUTO, HIGH,
    MED or LOW.
4. Push the ON/OFF  button, the  operation lamp  lights and the air
    conditioner start to  operate as  your settings. Push  the ON/OFF
    button again to stop this unit operation.

The  FAN mode can not be used to control the temperature. 
While in this mode, only steps 1

3 and 4 may be performed.

COOL/ HEAT (Cooling only model without) and 
FAN Operation

NOTE

Summary of Contents for RG51EU1

Page 1: ...STRATION Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner GT SENL 09CD I SENL 12CD I SENL 18CD I SENL 24CD I SENL 09CD...

Page 2: ...unction of LCD Liquid Crystal Display Fig 1 TEMP AUTO COOL DRY HEAT FAN HIGH MED LOW MODE FAN SPEED TIMER ON SLEEP ON OFF TIMER OFF AIR DIRECTION RESET LOCK 1 2 4 5 6 7 3 8 9 10 11 12 13 14 15 Environ...

Page 3: ...t is running under SLEEP operation mode it would be canceled if you press the MODE FAN SPEED or ON OFF button SWING Button Push this switch button to activate auto swing feature of the horizontal louv...

Page 4: ...wise battery leakage may damage the remote controller 3 The average battery life under normal use is about 6 months 4 Replace the batteries when there is no answering beep from the indoor unit or if t...

Page 5: ...will show TIMER OFF the last set time for the stopping operation and the signal h will be shown on the DIGITAL DISPLAY area You are now ready to reset the time of the STOP operation 3 Set the startin...

Page 6: ...GT SENL 09CD I SENL 12CD I SENL 18CD I SENL 24CD I SENL 09CD O SENL 12CD O SENL 18CD O SENL 24CD O...

Page 7: ...p rature 5 C 60 C Caract ristiques 1 Modes de fonctionnement AUTO automatique COOL climatisation DRY d shumidification HEAT chauffage mod le de chauffage climatisation seulement et FAN ventilation 2 F...

Page 8: ...aque fois que vous appuyez sur le bouton Pour d sactiver la minuterie vous n avez qu r gler le d lai 0 11 Bouton SLEEP Appuyez sur ce bouton pour passer en mode d conomie d nergie Appuyez de nouveau p...

Page 9: ...tiques sont toutes deux activ es 7 Indicateur de vitesse du ventilateur Appuyez sur le bouton FAN SPEED pour r gler la vitesse de ventilateur d sir e automatique faible moyenne ou lev e L affichage AC...

Page 10: ...r Apr s environ 2 secondes de plus l indicateur h dispara t et la temp rature s lectionn e s affiche de nouveau sur l affichage ACL 6 3 R glage du d lai de mise en marche et d arr t 3 1 Appuyez sur le...

Reviews: