background image

 

Infrared Thermometer

 

TE

E

R

M

H

O

D

M

S

R

 I

E

N

H

F

T

R

 

A

D

RE

ST-677

ST-677

 

HDS Infrared Thermometer

Instruction

 

 Manual

Summary of Contents for ST-677

Page 1: ...Infrared Thermometer TE E R M H O D M S R I E N H F T R A D R E ST 677 ST 677 HDSInfraredThermometer Instruction Manual...

Page 2: ......

Page 3: ...HDS Infrared Thermometer Instruction Manual Version 01 07 MAY...

Page 4: ...ons 4 Operation Instructions Unit Diagram Function 5 Techniques of Infrared Thermometer 6 Maintenance 1 1 Features 2 1 Cautions 4 1 Quick Start 4 2 4 3 Operation 4 4 C F Laser Switch and Battery Chang...

Page 5: ...d temperature and high DS ratio These allow user to monitor the target temperature for a long distance far away from the potential risk High DS ratio Adjustable emissivity from 0 1 to 1 00 in 0 01 ste...

Page 6: ...ed accuracy Dangerous refer to this manual before using the meter CE Certification D o n o t p o i n t l a s e r d i r e c t l y a t e y e U s e c a u t i o n a r o u n d r e f l e c t i v e s u r f a...

Page 7: ...ime 500 ms Emissivity Adjustable 0 1 1 0 Distance Spot Ratio 50 1 Supply Voltage 9V ati a l r m c l pp Auto Power Off Aut aft a rox 6s o e y Operating Temp 0 50 32 122 10 90 RH C F Switchable YES Back...

Page 8: ...point the unit at the target pull the trigger and hold Be sure to consider the target area inside the angle of vision of this instrument The single spot of laser is used for aiming only 4 2 Unit diagr...

Page 9: ...3 14 15 SCAN HOLD AUTO C F Indication Main Temperature Display Max Min Avg Set Record Value Lock Key Mode Key Up Button Laser Buzzer On Off Low Battery Data Log T Emissivity High Low Alarm Memory Key...

Page 10: ...play the temperature during measurement The maximum temperature within one shot measuring The minimum temperature within one shot measuring The average temperature within one shot measuring The highes...

Page 11: ...functions can be activated always in any step of operations mode in flow chart d In SCAN mode the LCD displays both the current tempera ture in Celsius or Fahrenheit The unit will HOLD the last readin...

Page 12: ...place the battery when the battery voltage drops below the voltage for reliable operation and at the same time the low battery symbol will appear To change the 9V battery pull open the unit s handle u...

Page 13: ...t operates and is determined by the optics of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the i m e closer you should be to it When the...

Page 14: ...measure moving and intermittent targets targets in a vacuum and targets that inaccessible due to hostile environments geometry limitations or safety hazard The cost is relatively high although in som...

Page 15: ...rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten iron 1299 1399 3...

Page 16: ......

Page 17: ......

Page 18: ...ST 677 Version 01 07 MAY 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000677 01...

Reviews: