Sentry Saf-T-Vise STV-XH1 Installation, Operation & Maintenance Manual Download Page 15

Saf-T-Vise STV-XH1 15

Customer Support

With proven sampling expertise since 1924, Sentry products and services provide business operations the critical 

insights to optimize process control and product quality . We deliver true representative sampling and analysis 

techniques to customers around the globe, empowering them to accurately monitor and measure processes for 

improved production effi  ciency, output, and safety . Standing behind our commitments, we are determined to tackle 

any application, anywhere .

We know that running an effi  cient operation isn’t easy . It requires thorough, careful analysis of controlled, real-

time data achieved through reliable, accurate, and repeatable process monitoring, and measuring . By eff ectively 

conditioning, sampling, and measuring gas, liquid, slurry, powder, solids, steam, or water within their production 

environments, our customers obtain the critical insights they need to control and optimize their processes .

Yet, controlling your processes also means reliable customer support throughout the life cycle of your equipment .

 

ƒ

Customer Service—General information, warranty claims, order management .

 

ƒ

Installation Service—For systems that require specialized expertise upon installation .

 

ƒ

Technical Support—Troubleshooting, training, and technical manuals .

 

ƒ

Field Service & Retrofi ts—When a problem needs immediate attention .

 

ƒ

Replacements Parts & Consumables—Order your replacement parts and consumables .

 

ƒ

Sentry ProShield Services—Select from four ProShield Guardian service plans providing diff erent levels of support to 

protect your large system investments with regularly scheduled maintenance .

To learn more, go to 

www .sentry-equip .com/support

 .

Summary of Contents for Saf-T-Vise STV-XH1

Page 1: ...Original Instructions Installation Operation Maintenance Manual Saf T Vise STV XH1 Insertable Tool Holders S CM IOM 00605 1 03 22...

Page 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Page 3: ...tallation and Operation 7 Maintenance 8 Inspecting the Safety Cap 8 Prepping the Tool Holder for Reinstallation 8 Cleaning the Rod Probe Shaft 8 Changing a Coupon 10 Troubleshooting 11 Leaks 11 Lockin...

Page 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Page 5: ...th any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very hot surf...

Page 6: ...ented locking collet which secures the rod within the process stream until released by the operator A process bleeder valve is standard on holders to allow depressurization of the holder after closure...

Page 7: ...e indicated 12 Point flange head cap screws as these are the only standard screws with a head diameter small enough to not interfere with the lower body The API flange version STV XH1 TF3KH44 can acco...

Page 8: ...ther fine viscosity lubricant 1 Remove the holder from the line 2 Loosen the locking collet bolt and slide the rod to the fully inserted position until the stop hits the top of the body Leave the lock...

Page 9: ...If the upper body is difficult to remove stop immediately and make sure that the set screw is loose 3 Replace the seal a With the upper body removed use a pick or small screwdriver to gently pick out...

Page 10: ...unique to each retrieval tool Be sure to keep the removed assembly with the specific tool retractor e Once the rod is through the body of the holder reinstall the locking collet if removed with the o...

Page 11: ...ed portion immediately isolate the holder from the line and remove process pressure 2 Remove the holder from the isolation valve 3 Remove the threaded component and use a small pick or screwdriver to...

Page 12: ...y Collets are matched to a body assembly during manufacturing and cannot be replaced separately Service Parts List STV XH1 TF44 Series Item Number Part Number Description Quantity 1 2 07786F 7 8 Lock...

Page 13: ...ctor tool is required to insert and retract the rods from the pipeline Note that the safety rod capture tube is critical to safely operating this tool It aims the rod through the top of the tool preve...

Page 14: ...n the table below Product Line Product Category Warranty Period Sentry 1 Automatic Sampling 2 Corrosion Monitoring 3 Manual Sampling 4 Sample Conditioning 5 Sampling Analysis Systems 6 Replacement Par...

Page 15: ...ioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize their pro...

Page 16: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Reviews: