The control valve has been pre-programmed from the factory with the correct regeneration cycle program and
cycle times. The gallon capacity between regeneration can be changed by adjusting the water hardness.
Step 1
- Press the
NEXT
and the
UP
Arrow buttons at the same time and hold for 2 seconds.
Step 2
-
Raw Water Hardness:
Adjust to the correct hardness by pressing the
UP
or
DOWN
arrow button. Default setting 20 grains per gallon. Press
NEXT
to go to Step 3.
Step 1
Step 2
Step 3
-
Day Override:
This setting should be set to
15
. Press
NEXT
to go to Step 4.
Step 4 - Regeneration Time:
The system regenerates at
2:00 AM
. This setting is adjustable. No
water should be used during regeneration. (Typically this is the middle of the night.)
Press
NEXT
to exit programming.
Step 3
Step 4
SET HARDNESS
20
SET
REGEN
DAY
15
REGEN
2:00
AM
GAL
Exit
Programming
Mode
Control Valve Programming
Summary of Contents for 972SM Series
Page 1: ...Single Metered Water Softening System 1 25 Operation and Maintenance Manual Series 972SM...
Page 2: ...2...
Page 14: ...14 Control Valve Programming Series 972 Control Valve Programming...
Page 15: ...15...
Page 19: ...19 Parts Breakdown Parts Breakdown...
Page 20: ...20...
Page 29: ...29 Parts Breakdown Bypass Valve Operation...
Page 35: ...35 Service Instructions Service Instructions...
Page 41: ...41 Troubleshooting the Control Valve Troubleshooting the Control Valve...
Page 42: ...42...
Page 48: ...48 OM A972SM Printed in the USA Version 160915 1...