2
Use as intended
The sole purpose of the wave.com4 touch operating element is to operate devices in the wave.com4 series.
In accordance with this provision, the wave.com4 touch operating element can be used in its full functionality.
The safety and usage information of the respectively connected devices also applies.
3
General description of function
The wave.com4 touch operating element automatically recognises connected devices. The respective
menu points appear according to the devices recognised.
Only connect and disconnect devices when the power is off.
The following operating modes and functions are available, dependent on the devices connected. See also
the table of available functions:
•
Finnish operation
•
Climate operation
•
Infrared operation
•
Sound and light effects
•
Ventilator
•
Cabin light
•
Programmes
One or more of the devices stated below may be used for power supply:
•
wave.com4 basic module (Finnish sauna)
•
wave.com4 basic module with extension module (combi sauna)
•
wave.com4 Infra
3.1 Table of available functions:
Function
Device
Finnish
operation
Climate/
combi-
operation
Colour
light
Sound
Cabin
light
3
Infrared
operation
Venti-
lator
4
2-sensor
regulation
WC4-B-L
YES
YES
1
YES
WC4-B-L +
WC4-H-PCB +
YES
YES
1
YES
YES
WC4-B-L +
WC4-H-PCB +
WC4-H-F2
YES
YES
1
YES
YES
YES
5
WC4-B-L +
WC4-H-PCB +
WC4-H-H
YES
YES
YES
1
YES
YES
WC4-B-L +
WC4-H-PCB +
WC4-H-F2 +
WC4-H-H
YES
YES
YES
1
YES
YES
YES
5
WC4-IRX-P
YES
1
YES
YES
YES
WC4-SL-L
YES
YES
2
1
External 8 Ohm loudspeaker necessary – not contained in scope of supply
2
The colour lamp is used as a loudspeaker. See also sound&light connection – only for experts.
3
When WC4-IRX-P and WC4-B-L are combined, a selection can be made in the system parameters with
regard to which device controls the cabin light.
4
When WC4-IRX-P and WC4-B-L are combined, a selection can be made in the system parameters with
regard to which device controls the ventilator.
5
The bench sensor must be activated in the system parameters.
Instructions for installation and use
P. 4/22