The heater panel may only be connected in strict compliance with these instructions! Never use anything
except the original cables and parts supplied. Only when these cables are used can the relevant standards
(conductor cross-section, insulation, temperature class etc.) be safely complied with.
•
It is not advisable to use the infrared cabin within 24 hours of exposing your skin to ultraviolet radiation from
an artificial source or from sunbathing.
•
If in doubt, people at risk of hyperthermia, such as those who suffer from cardiovascular conditions, should
consult a doctor before using an infrared cabin.
•
If persistent erythema (reddening of the skin for more than one day) or mottled skin discolouration occurs after
regular exposure to infrared radiation, do not repeat the exposure and consult a doctor to prevent it develop-
ing into the more serous condition erythema ab igne.
•
The heater panels have a built-in safety temperature limiter. Even so, the panels may only be connected to
a control unit that has temperature regulation and time limit functions.
•
The heater panel may only be used with the foil sensor installed.
• Subject to technical modifications.
2
Intended use
The heater panels are designed for installation in infrared and sauna cabins. They must always be used with
a control unit with temperature regulation and time limit functions.
Suitable control units: Wave.com4 Infra, IS1, IS2, IHF, CSI
Any other use (e.g. as a room heater) is explicitly prohibited and immediately invalidates the guarantee/warranty!
3
Installation instructions
Caution: Remove all packaging before putting the device into operation.
Warning: Never put screws through the black part of the heater panel.
Caution: The heater panel becomes very hot during operation. There must be adequate contact protection.
4 Installation
4.1 Installing the foil sensor
There are recesses in the back of the heater panel where the foil sensor of the control unit can be fitted.
If heater panels of different strengths are used in the same cabin, installing the foil sensor in the panel with the
lowest power rating or the one with the least favourable thermal conditions is recommended. For the position of
the sensor recesses, see point 4, “Position of the cable exits”.
4.2 Fastening the panel
A suitable frame must be used to fasten the heater panel. This must also offer suitable contact protection.