Installation instructions, only for experts
p. 7/12
4.2.
Installing the auto-refill unit
1.
Feed the water inlet pipe
3
through the installation opening next to the
evaporator until the ball valve is visible at the bottom.
2.
Remove the sealing cap of the evaporator tank connection
6
.
3.
Place the flat seal
4
into the union nut on the evaporator tank inlet pipe
5
.
4.
Connect the evaporator tank inlet pipe
5
to the evaporator tank connec-
tion
6
.
5.
Place the auto-refill unit
7
into the installation position intended.
6.
Screw on the auto-refill unit in four places using the screws provided.
3
4
5
7
6