Sentiotec Concept R  CP-RC-AF Instructions For Installation And Use Manual Download Page 1

Version 05/15 

ID no.  M100-000-219

EN

INSTRUCTIONS FOR INSTALLATION AND USE
English

Concept R 

AUTO REFILL SET

CP-RC-AF 

Summary of Contents for Concept R CP-RC-AF

Page 1: ...Version 05 15 ID no M100 000 219 EN INSTRUCTIONS FOR INSTALLATION AND USE English Concept R AUTO REFILL SET CP RC AF ...

Page 2: ...nctions 5 4 Installation and connection to sauna heater Concept R combi 6 4 1 Preparing the sauna heater 6 4 2 Installing the auto refill unit 7 5 Installation and connection to auxiliary evaporator Concept R 8 5 1 Preparation of the auxiliary evaporator 8 5 2 Installing the auto refill unit 9 6 Connecting the water inlet pipe 10 7 Function test 10 8 Troubleshooting 10 9 Cleaning and maintenance 1...

Page 3: ...bserved at all times This prevents damage to property and injuries which in the worst case may be fatal The warning symbols contain keywords with the following meanings DANGER Serious or fatal injury will occur if this warning symbol is not observed WARNING Serious or fatal injury may occur if this warning symbol is not observed CAUTION Minor injuries may occur if this warning symbol is not observ...

Page 4: ...auto refill set is suitable for the following models CP RC 090 CP RC 105 CP 25 STP Any use exceeding this scope is considered improper Improper use can result in damage to the product severe injuries or death 2 2 Safety information for the installer The fixed water connection should be installed only by a qualified installer or a comparably qualified person according to the local provisions of the...

Page 5: ... This valve ensures that fresh water flows into the evaporator tank until the float rises and makes the water valve close again Observe the minimum and maximum supply water pressure speci fied in the technical data see 11 Technical data on page 12 A drain must be located at the bottom of the sauna room in case the water line is damaged or begins to leak For the connection only use the hose set inc...

Page 6: ...d only be performed on the sauna heater once it has cooled down 4 1 Preparing the sauna heater Make sure that the sauna heater has completely cooled down and remove the ceramic bowl for herbs and aromas 1 Remove the steam funnel 2 located under the evaporator tank Remove the strut 3 with a suitable screwdriver WARNING Risk of electric shock The sauna heater may only be installed and connected when...

Page 7: ...ll valve is visible at the bottom 2 Remove the sealing cap of the evaporator tank connection 6 3 Place the flat seal 4 into the union nut on the evaporator tank inlet pipe 5 4 Connect the evaporator tank inlet pipe 5 to the evaporator tank connec tion 6 5 Place the auto refill unit 7 into the installation position intended 6 Screw on the auto refill unit in four places using the screws provided 3 ...

Page 8: ...ed on the auxiliary evaporator once it has cooled down 5 1 Preparation of the auxiliary evaporator Make sure that the auxiliary evaporator has completely cooled down and remove the ceramic bowl for herbs and aromas 1 Remove the steam funnel 2 located under the evaporator tank Remove the strut 3 with a suitable screwdriver 1 2 WARNING Risk of electric shock The auxiliary evaporator may only be inst...

Page 9: ...ll valve is visible at the bottom 2 Remove the sealing cap of the evaporator tank connection 6 3 Place the flat seal 4 into the union nut on the evaporator tank inlet pipe 5 4 Connect the evaporator tank inlet pipe 5 to the evaporator tank connec tion 6 5 Place the auto refill unit 7 into the installation position intended 6 Screw on the auto refill unit in four places using the screws provided 7 ...

Page 10: ... water inlet pipe fully 2 Open the ball valve of the water inlet pipe fully The evaporator tank fills up with water Once the maximum mark is reached the evaporator tank stops filling up automatically 3 Start the evaporator When the water level in the evaporator tank drops the auto refill unit fills it up with water automatically 8 Troubleshooting If the evaporator tank does not fill up automatical...

Page 11: ...n accordance with the applicable disposal regulations Used devices contain reusable materials as well as hazardous substances Do not dispose of your used device with household waste but do so in accordance with the locally applicable regula tions 9 Cleaning and maintenance The auto refill set is maintenance free ...

Page 12: ... water supply pressure 30 kPa 0 3 bar Maximum water supply pressure 600 kPa 6 bar If pressure is over 600 kPa 6 bar Pressure limiter standard regulator mounted between the fixed water connection and the auto refill unit Fixed water connection 1 2 1 27 cm Tank dimensions Length 135 mm Width 135 mm Depth 255 mm Length of connection lines Water inlet pipe 1000 mm Evaporator cable 500 mm ...

Page 13: ...sentiotec GmbH world of wellness Oberregauer Straße 48 4844 Regau Austria T 43 0 7672 277 20 800 F 43 0 7672 277 20 801 E info sentiotec com www sentiotec com ...