background image

Doc.. 6001141

Doc.. 6001141

Doc.. 6001141

Doc.. 6001141

Rev B

Rev B

Rev B

Rev B

CROWN JEWEL

CROWN JEWEL

CROWN JEWEL

CROWN JEWEL

ADVANCED FEATURES

ADVANCED FEATURES

ADVANCED FEATURES

ADVANCED FEATURES

PROGRAMMING GUIDE

PROGRAMMING GUIDE

PROGRAMMING GUIDE

PROGRAMMING GUIDE

Summary of Contents for CROWN JEWEL

Page 1: ...1141 Doc 6001141 Rev B Rev B Rev B Rev B CROWN JEWEL CROWN JEWEL CROWN JEWEL CROWN JEWEL ADVANCED FEATURES ADVANCED FEATURES ADVANCED FEATURES ADVANCED FEATURES PROGRAMMING GUIDE PROGRAMMING GUIDE PROGRAMMING GUIDE PROGRAMMING GUIDE ...

Page 2: ......

Page 3: ... SCHEDULE STEP 11 9 D DELETING A DO NOT DISTURB SCHEDULE STEP 11 10 E ENABLING DISABLING THE DO NOT DISTURB SCHEDULE STEP 12 10 PART 6 GATE CONFIGURATION 11 A SETTING THE MAIN GATE ACTIVATION TIME STEP 23 11 B SETTING AUXILIARY RELAY AND STATUS 2 INPUT CONFIGURATION STEP 26 11 C SETTING AUXILIARY RELAY ACTIVATION TIME STEP 24 12 PART 7 UNLOCK SCHEDULES 13 A SETTING AN UNLOCK SCHEDULE FOR THE MAIN ...

Page 4: ...E STEP 99 23 PART 11 OTHER FUNCTIONS 24 A SETTING ALTERNATE PREFIXES STEP 36 24 B RESTORING FACTORY SETTINGS STEP 31 25 C ENABLING DISABLING THE NO TELCO MODE STEP 33 25 D RINGS BEFORE ANSWER STEP 29 26 E OVERRIDING TELEPHONE COMPANY ANSWERING SERVICE STEP 43 26 F RESETTING THE UNIT STEP 32 26 PART 12 MULTIPLE UNIT INSTALLATIONS 27 A PROGRAMMING MULTIPLE UNITS 27 B SETTING THE UNIT NUMBER STEP 38 ...

Page 5: ... document contains information proprietary to Sentex and such information may not be distributed without the prior written consent of Sentex The software and firmware included in the Sentex Crown Jewel unit as they relate to this documentation are also protected by copyright and contain information proprietary to Sentex Sentex Systems Chatsworth CA Visit us at www sentexsystems com ...

Page 6: ...Doc 6001141 Rev B ...

Page 7: ...ough the use of 4 digit entry codes You can program up to 75 different entry codes to allow access through the Crown Jewel unit Time Zones You can restrict the use of entry codes by limiting the days and times that a code is valid Call Forwarding The Crown Jewel unit can be programmed to dial an outside telephone number instead of ringing the house when a visitor presses a key on the front panel o...

Page 8: ...ask your installing dealer for details on how these records may be retrieved via modem B PROGRAMMING BASICS You can program the Crown Jewel from The keypad mounted on the face plate of the unit The residence telephone you will need a tone dial telephone A remote telephone you will need to use a tone dial telephone to call the residence ENTER PROGRAMMING MODE Begin by signalling the Crown Jewel uni...

Page 9: ... 00 two zeroes and the pound key Keypad the unit will disconnect Telephone residence or remote the unit respond with three short beeps Hang up the phone C SETTING THE DATE AND TIME STEP 27 The Crown Jewel unit contains an internal calendar and clock which is used for Time stamping of transactions The Do Not Disturb feature Entry codes with time zones Gate unlock schedules Call Forwarding schedules...

Page 10: ...de memory is full 4 long beeps the unit has reset or is powering up busy signal the line is busy or Do Not Disturb feature is in effect Direct Command Responses 5 short beeps a gate is closing by command 10 short beeps a gate is opening by command Other Responses 1 short beep a key was pressed on the main keypad 10 beeps 1 per second the talk time for a visitor call is lapsing and the unit will be...

Page 11: ...end at 5 00 PM Monday through Friday and holidays Note To set up a time zone that extends past midnight and into the next day create one segment that runs until midnight for example Monday through Friday from 8 PM to 12 AM and a second segment that starts at midnight on the following days for example 12AM to 4AM on Tuesday through Saturday If you want a time zone to be valid on holidays you must a...

Page 12: ...rmal activation times 9 Latch both Time Zones are one digit long Examples Entry code for main gate valid at all times 03 2468 sets entry code 2468 to activate the main relay valid at all times Entry code with relay code only 03 3579 2 sets entry code 3579 to cycle the auxiliary relay for the normal activation time Entry code with Time Zone code only 03 9631 3 sets entry code 9631 to cycle the defa...

Page 13: ...scontinue the visitor call after 6 rings to the house C SETTING TALK TIME STEP 08 Sets the maximum length of a call that can be made by a visitor Factory Settings 90 seconds Format 08 number of seconds This length can be set from 15 to 250 seconds the entry will be two or three digits long Example 08 120 sets the talk time to 2 minutes NOTES 1 When the Crown Jewel is calling the residence during a...

Page 14: ...you press on your telephone keypad in response to visitor calls Factory Setting 9521 9 for Main Gate activation 5 for Auxiliary Relay activation 2 for Call Waiting Toggle Digit 1 for Extend Talk Time Digit for Hang up Key Format 34 main gate activation digit auxiliary relay activation digit call wait toggle digit extend talk time digit hang up digit Example 34 1 2 6 7 8 Changes main gate activatio...

Page 15: ...B CANCEL DO NOT DISTURB UNTIL STEP 89 The procedure cancels call blocking immediately Format 89 99 Enter 99 as the ending time C SETTING UP A DO NOT DISTURB SCHEDULE STEP 11 Use this programming step to block calls at regularly scheduled times Format 11 day of the week starting time ending time holiday option Day of the week is one digit long 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Fr...

Page 16: ...ng time Example 11 2 99 Deletes the Do Not Disturb schedule for Mondays E ENABLING DISABLING THE DO NOT DISTURB SCHEDULE STEP 12 Use this programming step to temporarily disable or re enable the Do Not Disturb Schedule Factory Setting 0 disabled Format 12 Do Not Disturb mode 1 digit Do Not Disturb mode is one digit long 0 Ignore Do Not Disturb Schedule 1 Enable Do Not Disturb Schedule Example 12 1...

Page 17: ...TATUS 2 INPUT CONFIGURATION STEP 26 You can program the modes of operation of the auxiliary relay and the status 2 input The auxiliary relay can be used to Control a second gate Bypass shunt an alarm sensor Trigger an alarm device such as a siren Activate an accessory such as CCTV The status 2 input can be used as An exit request for the second gate A sensor to detect the closed position of the ma...

Page 18: ...o terminate the call 4 The closed circuit TV will activate when any key is pressed on the main keypad 5 During a visitor call the relay will only activate when you dial a 5 and then the call will be terminated C SETTING AUXILIARY RELAY ACTIVATION TIME STEP 24 You can program the amount of time the auxiliary relay will remain activated Factory Setting 10 seconds Format 24 number of seconds up to 3 ...

Page 19: ...egment opening time closing time holiday option The day of the week is one digit long 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Holidays The segment is one digit long either 1 or 2 The opening and closing times are four digits long in 24 hour format The holiday option is one digit long 0 No schedule on holidays 1 Use same schedule on holidays 2 Use schedule number 8 ...

Page 20: ...day of the week is one digit long 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Holidays The segment is one digit long either 1 or 2 The opening and closing times are four digits long in 24 hour format The holiday option is one digit long 0 No schedule on holidays 1 Use same schedule on holidays 2 Use schedule number 8 when this day falls on a programmed holiday Example ...

Page 21: ...he segment is one digit long either 1 or 2 Example 42 2 1 99 Erase the Monday Segment 1 Unlock Schedule for the Auxiliary Gate E ENABLING DISABLING UNLOCK SCHEDULES STEP 40 You can temporarily disable or re enable the Unlock Schedules Factory Setting Ignore Unlock Schedules Format 40 Unlock Schedule mode The Unlock Schedule mode is one digit long 0 Ignore Unlock Schedules 1 Re enable Unlock Schedu...

Page 22: ... sets the Call Forwarding number to 555 1212 NOTE During a Call Forwarding call the visitor will hear normal telephone line sounds but will not hear the number being dialed B ENABLING DISABLING CALL FORWARDING STEP 13 You can program the Crown Jewel to forward calls to stop forwarding calls or to forward calls according to the Scheduled Call Forwarding feature see Section G NOTE To use Call Forwar...

Page 23: ...ample 15 22 enters a pause of 22 seconds between the Call Forwarding number and the Forward Call extension number F DISABLE THE CALL FORWARDING EXTENSION DELAY STEP 15 Format 15 number of seconds Enter 0 seconds to disable Call Forwarding Extension Delay Example 15 0 Disables Call Forwarding Extension Delay NOTE In order for the unit dial an extension number the Call Forwarding and Call Forwarding...

Page 24: ...y 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Holidays The starting and ending times must be four digits long in 24 hour format The holiday option is one digit long 0 No schedule on holidays 1 Use same schedule on holidays 2 Use schedule number 8 when this day falls on a programmed holiday Example 18 2 0900 1800 0 sets the Call Forwarding schedule for Mondays to forward all vis...

Page 25: ... exit programming The number that you entered does not match the password Repeat steps 01 and 02 until you are certain that the password is what you want If you typed the password incorrectly or you forget the password you can reset the Crown Jewel to the factory defaults using programming step 31 See Part 11 Section B C ENABLING DISABLING ALARM CALL STEP 21 Programs the unit to make an alarm call...

Page 26: ...2 The number of keypad errors for keypads 1 and 2 is one digit long from 0 to 9 0 No limit to the number of keypad errors If you do not have a second keypad press after the number of keypad error for keypad 1 Examples 20 3 sets keypad 1 to stop accepting codes after 3 unsuccessful attempts 20 4 3 sets keypad 1 to block after 4 unsuccessful attempts and keypad 2 to stop accepting codes after 3 unsu...

Page 27: ... feature Example 89 99 Cancel the Do Not Disturb Until feature C SPEAK THROUGH THE CROWN JEWEL MICROPHONE STEP 90 You can initiate communications from a telephone through the Crown Jewel s speaker and microphone at any time to greet visitors ward off vandals etc Format 90 NOTE 1 This call will terminate automatically in 60 seconds unless you hang up the line sooner 2 Extend the talk time by pressi...

Page 28: ...e any existing unlock schedules 2 You may also use this step to unlock a gate prior to an unlock schedule The gate will remain open up until and through the unlock schedule for that day When the unlock schedule ends the gate will close as it would normally on that day H RELEASE MAIN GATE RELAY STEP 95 You can activate the main relay until released by another program step a direct command or an ent...

Page 29: ...ily extend an unlock period beyond the scheduled closing time Enter an ending time after the scheduled closing time L LATCH AUXILIARY RELAY UNTIL SPECIFIED TIME STEP 99 You can activate the auxiliary relay until the time you specify in this step Format 99 ending time The ending time must be four digits long in 24 hour format Example 98 1730 latches auxiliary door open until 5 30 PM NOTE This step ...

Page 30: ...fix mode The alternate prefix mode must be 2 digits long 00 normal the prefix for Direct Commands is the prefix for entering programming mode is followed by the 6 digit password 01 mixed the prefix for the Direct Commands is a combination of the two keys i e or the prefix for programming is a combination of three keys i e or 02 stars the Direct Commands prefix is the prefix for programming is 03 p...

Page 31: ... Call Forwarding Disabled 20 Maximum Number of Keypad Errors 5 for Keypad 1 5 for Keypad 2 21 Enabling Disabling Alarm Call Disabled 23 Setting the Main Gate Activation Time 10 seconds 24 Setting Auxiliary Relay Activation Time 10 seconds 26 Setting Auxiliary Relay and Status Configuration Control relay exit request 2 29 Rings Before Answer 5 34 Programming Visitor Response Keys 9 5 2 1 36 Program...

Page 32: ...e Crown Jewel unit can be remotely programmed even if the answering machine answers the line first E OVERRIDING TELEPHONE COMPANY ANSWERING SERVICE STEP 43 You can override the answering service by dialing the line attached to your unit letting the phone ring once or twice only then hanging up After a few seconds dial the same number again The Crown Jewel will answer the second call immediately if...

Page 33: ...s 2 Enter the unit ID code 3 Enter the six digit password The unit will emit a high pitched tone 4 Press the pound key The tone will stop 5 The Crown Jewel is now ready to accept programming isntructions From a Remote Telephone 1 Dial the residence telephone number 2 When the Crown Jewel picks up the call press the asterisk key three times 3 Enter the unit ID code 4 Enter the six digit pass word T...

Page 34: ...ogramming step to verify each unit s ID code in a multiple unit chain Format 37 The unit will respond with the number of beeps corresponding to its unit number Example Unit 1 will respond with one beep unit 2 will respond with two beeps unit 3 will respond with 3 beeps etc ...

Page 35: ...e dial tone press the pound key twice the unit ID code if applicable then the six digit password 2 The Crown Jewel is now ready to accept programming instructions Examples 123456 enter direct command mode 3 030303 enter direct command mode for unit three B DO NOT DISTURB UNTIL STEP 89 You can activate the Do Not Disturb Until feature using a Direct Command Format 89 ending time The ending time mus...

Page 36: ...step 97 below H ACTIVATE AUXILIARY RELAY STEP 94 Use this Direct Command to activate the auxiliary relay until you release it Format 94 NOTE To deactivate the auxiliary relay see Section J step 96 or Section K step 97 below I DEACTIVATING MAIN RELAY STEP 95 Use this Direction Command to deactivate the main relay close the main gate Format 95 NOTE This step will temporarily override any existing un...

Page 37: ... digits long in 24 hour format Example 99 2000 Activates the auxiliary relay until 10 00 pm NOTE This step will temporarily override any existing unlock schedules N USING THE IN HOUSE PAGING FEATURE You can send the Crown Jewel a Direct Command that will cause all the telephones connected to the unit s phone line to give a distinctive ring For example you can use this command to page someone else ...

Page 38: ...umber up to 11 0 through 9 00 disables the number 15 Setting the Call Forwarding Extension Delay up to 2 0 through 30 seconds 16 Setting the Call Forwarding Extension Number up to 6 00 disables the number 17 Setting the Maximum Number of Digits in the Call Forwarding Extension Number 1 0 through 6 18 Setting the Call Forwarding Schedule 3 or 10 day of the week starting time ending time holiday opt...

Page 39: ...the Unit Number 2 this unit number total number of units 40 Enabling disabling Unlock Schedules 1 0 disable 1 enable 41 Setting the Main Gate Unlock Schedule up to 11 day of the week segment number starting time ending time holiday option 99 erases 42 Setting the Auxiliary Relay Unlock Schedule up to 11 day of the week segment number starting time ending time holiday option 99 erases 43 Overriding...

Reviews: