Page 5 of 8
Doc 6001051, Rev C
Mag Locks
TB1
COM1
COM2
NC1
NC2
1051F8
2 / 18-22 AWG
+
+
DC POWER SOURCE
MAG LOCK
1N4001
Diode or
equiv.
Relay 1: Connect as Shown.
Relay 2: Connect wires
to COM2 and NC2
Figure 7: Mag Locks
WARNING:
In order to prevent voltage spikes generated by magnetic lock or DC powered strikes from
being induced into the system, it is strongly recommended that a 1N4001 diode be installed
across the magnetic lock coil, so that the cathode of the diode (the end with the band) is
connected to the positive connection of the coil and the anode is connected to the negative
connection of the coil.
For Dry Contact Closure (Most Gate Operators)
1051F13
MOST GATE OPERATORS
(Dry Contact Closure)
TB1
COM1
COM2
NO1
NO2
2 / 18-24 AWG
Relay 1: Connect as Shown.
Relay 2: Connect wires
to COM2 and NO2
Figure 8: Dry Contact Closure Connections