background image

ST230F TELEPHONE LINE TESTER 

 

8

 

 

 

 

 

 

 

 

 

 

 

On  the  one  end(END  A)  of  the  cables,  use  the  ST230F  black  alligator  clamping  one  cable  and  red  alligator  clamping 

another cable, On the other end (END B), we name the cable with red alligator as the assistant cable. Use the telephone 

or ST230F clamping the same two cables to confirm normal talk. Then at the other end (END B), choosing any waiting 

checked cable connects with assistant cable, after that, on the end (END A),    you should insert single alligator cable into 

the charge hole, using this single alligator to connect any of waiting checked cables, when you hear the long “Du…” sound, 

you find the checked cable. 

 

6.6 Monitor   

High resistance monitoring function helps operators choose/check line without influence to the user telephone and digital 

service. This can less user complaints and avoids interruption of user data service.   

Has high resistance monitor function,   

Usage:   

 

Press button

, the MONITOR indicator light is on. The tester enters into Monitor & Identifying state.   

 

Connect  line  clamps  to  telephone line  that  is  being  used,  the  tester can  clearly  hear  voice  call in the line,  and the 

DATA-LED

 light will be bright accompanying the talk. 

 

Connect clamps to ISDN network, 

DATA-LED

 light will be bright when user uses this service, and there will be rustle 

sound  in  the  receiver,  if  there  is  no  user  using  this  service,  you  will  hear  code  stream  sound  like  da,da…and 

occasionally rustle sound. 

 

Connect clamps to ADSL line, 

DATA-LED

 light will be bright when user uses this service, and there is no sound in the 

line, if there is no user using this service, 

DATA-LED

 light is not bright. 

 

6.7 High AC voltage alarm   

Press 

“Phone/Tester” 

and  then  press

    when  the  ST230F  is  near  the  line  circuit  which  has  high  AC  voltage; 

LED on and there is alarm sound. Please take care and operate it carefully! 

Purpose: the safety of the line can be tested before using this function and to avoid the danger effectively.   

Notice: This function is the accessorial function, please operate it according to the manual and the manufacturer 

does not respond for damages caused by using this function. 

 

6.8 Low voltage self-checking 

After  pressing  “Phone/Tester”,  if  it  displays              and  there  is  the  sound  “di  di…”, it  means  the  battery  is  low  voltage. 

Please loose “Phone/Tester” and charge the tester. 

 

 

   

6.9 Charge   

Insert the output plug of charger into charge hole, and then insert the charger into 220V socket. The charge indicator light 

Summary of Contents for ST230F

Page 1: ...ST230F TELEPHONE LINE TESTER USER MANUAL Shandong Senter Electronic Co Ltd ...

Page 2: ...orage and dial function 6 6 1 7 Data lockout override function 6 6 1 8 Mute function 6 6 1 9 P T transfer function 6 6 1 10 High DC voltage indication 6 6 2 Tester test 6 6 2 1 AC V DC V test 6 6 2 2 Insulation test 7 6 2 3 Open line test 7 6 2 4 Earth insulation 7 6 3 Call user talk 7 6 4 Phone test 7 6 5 Check wire pairs 7 6 6 Monitor 8 6 7 High AC voltage alarm 8 6 8 Low voltage self checking 8...

Page 3: ...lowing the human engineering theory with the appearance style like barbell it can be put on the shoulder the lineman can do other work using hands at the same time besides it can be hung in the tool belt of waist through the pothook it is convenient to realize the talk function cooperating with the high quality earphone when the lineman is climbing or doing other things the max continuous working ...

Page 4: ...ndicator will be light Data LED indicator If there is living data ADSL service on the line when you do the data identification operation the data indicator will be light 13 H ACV LED indicator If there is high AV voltage on the line the H ACVA indicator will be light 14 LCD Display telephone number and test result 2 3 Test faceplate Phone Tester Press it to enter test status loose it to enter tele...

Page 5: ...ller telephone number display FSK DTMF auto compatibility DTMF applying to GB T15279 94 Dialing number display Hands free louder speaker function which can free your hands to do other operations Telephone number storage and dial function Data lockout override function Mute function P T transfer function ADSL ISDN identification High voltage indication Checking wire pairs function as the cable trac...

Page 6: ...is ringing press Hook to end talk 6 1 3 Redial Press REDIAL you can redial last telephone number If it is busy please hang and press redial again 6 1 4 Caller telephone number display This function is only used in the line which has caller telephone number display service The caller telephone number will be displayed when it receives the TSK or DTMF incoming call The number can be refreshed automa...

Page 7: ...ok in order not to damage the tester 6 1 8 Mute function Loose all keys connect clamps to the telephone line off hook and press MUTE the other side can not hear our voice and press MUTE again it becomes normal 6 1 9 P T transfer function Loose all keys under test status and no ringing signal this tester can do P T transfer operation Pressing more than 3 seconds can realize pulse dialing and tone d...

Page 8: ...ther the fault has been canceled or not through the line insulation test after checking the user line 6 2 3 Open line test In the normal status connect the tester to the line which will be tested and press Pone Tester after confirm there is no voltage in the line keep pressing Test for about 3 seconds It means that the line is break if the LCD only displays MΩ 6 2 4 Earth insulation Like the above...

Page 9: ... and the DATA LED light will be bright accompanying the talk Connect clamps to ISDN network DATA LED light will be bright when user uses this service and there will be rustle sound in the receiver if there is no user using this service you will hear code stream sound like da da and occasionally rustle sound Connect clamps to ADSL line DATA LED light will be bright when user uses this service and t...

Page 10: ...e higher the voltage which is tested is the longer the distance of electromagnetic eradiation is and the longer the test distance is the rain snow and fog can absorb part of electromagnetism therefore the test distance is small if there is other barriers such as trees house wall and so on and they can absorb part of electromagnetism and the distance is small Please loose all the keys to avoid disc...

Page 11: ...l It can be inserted into distribution frame conveniently to test the line through the terminal box SHANDONG SENTER ELECTRONIC CO LTD NO 98 WANJIE RD NEW HI TECH AREA ZIBO SHANDONG CHINA P C 255086 TEL 86 533 3589257 FAX 86 533 3587522 WWW SENTER COM CN export senter com cn ...

Reviews: