Page 11
A. Install EasyAG probe
Figure 8 EasyAG PLUS interface and wiring diagram
a) Slide the probe into the access tube.
b) Insert the probe cable through the cable gland into the access tube, ensuring cable is looped
around ferrite bead as near to cable gland as practical (see
). Tighten the cable gland on
the cap with a spanner.
c) Strip the outer grey sheath of the cable back, trim out the unused string, shielding and grey wire,
and then strip about 10mm insulation from each remaining coloured wires.
d) Twist the exposed copper wire and fold in half. Then fasten into the probe connector according to
the diagram in
B. Install EnviroSCAN Screw Cap probe
Hint:
Insert cable into Screw Cap and wire into interface connector before gluing Cap onto
the access tube to avoid compromising the glue seal.
a) Insert the probe cable through the cable gland into the access tube, ensuring cable is looped
around ferrite bead as near to cable gland as practical (see
). Tighten the cable gland on
the cap with a spanner.
Hint:
Pull enough cable through into the Screw Cap so that it can wrap around the handle
b) Strip the outer grey sheath of the cable back, trim out the unused string, shielding and grey wire,
and then strip about 10mm insulation from each of remaining coloured wires.
c) Twist the exposed copper wires and fold in half. Then fasten into the probe connector according to
the diagram in
Figure 9 EnviroSCAN interface and wiring diagram
d) Insert the probe into the tube and plug the connector in.