background image

     STC-MBA5MUSB3/MCA5MUSB3 

Product Specifications 

Ver 1.00 

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).  NO USER SERVICEABLE
PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the product’s
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

!

Warning:

This equipment generates and uses radio frequency energy and if
not installed and used properly, I.e., in strict accordance with the
instruction manual, may cause harmful interference to radio
communications.  It has been tested and found to comply with the
limits for a Class A computing device pursuant to Subpart J of Part
15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial
environment.

For U.S.A.

Warning:

This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of
Communications.

For Canada

WARNING:

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).  NO USER SERVICEABLE
PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the product’s
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

!

Warning:

This equipment generates and uses radio frequency energy and if
not installed and used properly, I.e., in strict accordance with the
instruction manual, may cause harmful interference to radio
communications.  It has been tested and found to comply with the
limits for a Class A computing device pursuant to Subpart J of Part
15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial
environment.

For U.S.A.

Warning:

This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of
Communications.

For Canada

WARNING:

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.

!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).  NO USER SERVICEABLE
PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The lightning flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the product’s
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

!

Warning:

This equipment generates and uses radio frequency energy and if
not installed and used properly, I.e., in strict accordance with the
instruction manual, may cause harmful interference to radio
communications.  It has been tested and found to comply with the
limits for a Class A computing device pursuant to Subpart J of Part
15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial
environment.

For U.S.A.

Warning:

This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of
Communications.

For Canada

WARNING:

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.

Safety Precautions 

Product Precautions 

Handle the camera with care. Do not abuse the camera. Avoid striking or shaking it. Improper handling
or storage could damage the camera.

Do not pull or damage the camera cable.

During camera use, do not wrap he unit in any material. This will cause the internal temperature of the
unit to increase.

Do not expose the camera to moisture, or do not try to operate it in wet areas.

Do not operate the camera beyond its temperature, humidity and power source ratings.

While the camera is not being used, keep the lens or lens cap on the camera to prevent dust or
contamination from getting in the CCD or filter area and scratching or damaging this area.

Do not keep the camera under the following conditions:

In wet, moist, and high humidity areas

Under hot direct sunlight

In high temperature areas

Near an object that releases a strong magnetic or electric field

Areas with strong vibrations

Use a soft cloth to clean the camera. Use pressured air spray to clean the surface of the glass. DO not
scratch the surface of the glass.

For More Information Please Call 

Aegis Electronic Group, Inc. * (888) 687-6877 Phone * [email protected] * http://www.aegiselect.com

Aegis 

Electronic 

Group 

www.aegiselect.com

Summary of Contents for STC-MBA5MUSB3

Page 1: ...USB 3 0 Camera STC MBA5MUSB3 STC MCA5MUSB3 ...

Page 2: ...o noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications For Canada WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO ...

Page 3: ...rs in listings specifications part numbers process software or model applications Sentech America reserves the right to change specifications product descriptions product quality pricing and application at any time without prior written or oral notice Any party using such information assumes all risk for any and all damaged caused to themselves a third party and or property by virtue of incorrect ...

Page 4: ...teristics 7 8 C Mechanical Specifications 9 D Environmental Specifications 9 III Interface Connector Specifications 10 A USB Connector 10 B I O Connector 10 IV Input Output Specifications 11 17 A Input Signals 11 12 B Output Signals 13 17 V Dimensions 18 For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c ...

Page 5: ... 1 Disable the power save mode by changing the BIOS settings Either set ACPI C State to Disable or decrease the Max ACPI C State value step by step until you see the effect i e C3 C2 C1 The setting method and the naming may differ and or these settings cannot be changed depending on the PC Please contact the manufacturer of the PC about the BIOS setting ACPI C State and Max ACPI C State may have d...

Page 6: ...ctronic Shutter Free run Mode Exposure Time 32 µsec to 38sec in full scanning mode Edge Preset Trigger Mode Exposure Time 32 µsec to 38sec in full scanning mode Pulse width Trigger Mode Exposure Time 32 µsec to unlimited in full scanning mode Gain Analog 0 to 26 97 dB Digital 0 to 12 04 dB Digital Clamp 0 to 255 LSB of 12bit output Gamma 0 1 to 4 0 settable with 0 1 step AOI AOI Horizontal 32 to 2...

Page 7: ...ctral Sensitivity Characteristics 1 STC MBA5MUSB3 2 STC MCA5MUSB3 For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n i c G r o u p w w w a e g i s e l e c t c o m ...

Page 8: ...cations 8 Ver 1 00 3 NF 50D IR Cut Filter For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n i c G r o u p w w w a e g i s e l e c t c o m ...

Page 9: ...nector USB3 0 MicroB type I O Connector HR10A 7R 6PB Hirose or equivalent D Environmental Specifications Model Number STC MBA5MUSB3 STC MCA5MUSB3 Operational Temperature 0 40 Storage Temperature 30 65 Vibration 20Hz to 200Hz to 20Hz 5min cycle acceleration 10G 3 directions 30 min each Shock Acceleration 38G half amplitude 6ms 3 directions 3 times each Standard Compliancy EMS EN61000 6 2 EMI EN5501...

Page 10: ...B connector via USB bus which carries 5V This 5V does not affect the voltage of output signals Pin Assignment Pin No Signal Name IN OUT Voltage Low High 1 GND IO_GND 0V 2 Output 2 IO3 OUT Smaller than 0 8 V 3 to 26 4 V 3 Output 1 IO2 OUT Smaller than 0 8 V 3 to 26 4 V 4 Input 2 IO1 IN Smaller than 0 7 V 1 7 to 5 V 5 Input 1 IO0 IN Smaller than 0 7 V 1 7 to 5 V 6 Power Input IO_VCC 3 to 26 4Vdc I O...

Page 11: ...rigger signal in the edge preset mode and for the start trigger in the start and stop trigger mode 4 Sub trigger Input Use this function for the stop trigger in the start and stop trigger mode 2 Input Signals Electronic Characteristics Input Signal Input Voltage 0 to 5V Input Signal Voltage Level High Level 1 7V min Low Level 0 7V max Function No Function Name Polarity 1 Disabled Default 2 General...

Page 12: ...0 ohm 10k ohm IO_GND internal power is applied CUS03 Tos hiba 1 2 IO_GND MAX_5V CAMERA GND SN74LVC2G241YZPR T I INPUT USER INPUT 100 ohm 10k ohm IO_GND internal power is applied CUS03 Tos hiba 1 2 IO_GND CAMERA SN74LVC2G241YZPR T I GND T r MAX_5V For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n ...

Page 13: ...first line exposure Trigger Out Delay and Trigger Pulse Width settings are applied 6 Read End Output Output a signal upon the completion of the transfer of a full frame Trigger Out Delay and Trigger Pulse Width settings are applied 7 Strobe Output Programmable Output a signal for the period set with strobe end delay starting at the trigger input signal with the addition of strobe start delay 8 Str...

Page 14: ...gative polarity setting low status indicates that the input trigger signal is acceptable This signal becomes high from the exposure start to the end of image output Because this camera is a rolling shutter type the exposure start timing of each line is not simultaneous For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e...

Page 15: ...in Output Signal Response Timing The response timing shown below is a reference value measured without an eternal resistance 2 04 us 1 16 us 0 66 us 0 56 us Tf 0 70 us 0 56 us 0 56 us 0 50 us Ts 1 44 us 1 16 us 0 84 us 0 82 us Tr 1 60 us 1 66 us 1 82 us 2 00 us Td 24 V 12 V 5 0 V 3 3 V IO_VCC 10 90 Td Ts Tr Tf INTERNAL SIGNAL USER OUTPUT 3 3V 0V IO_VCC IO_GND For More Information Please Call Aegis...

Page 16: ...e IO_VCC must be within the range of 3V to 26 4V USER OUT PUT DTC144EM Rohm 22k ohm IO_VCC CUS03 Tos hiba 1 2 IO_GND OUT PUT CAMERA 100 ohm GND For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n i c G r o u p w w w a e g i s e l e c t c o m ...

Page 17: ...to 26 4V The incoming current to IO2 and IO3 USER_lc must be less than or equal to 15mA IO_VCC USER_GND USER OUT PUT DTC144EM Rohm 22k ohm IO_GND CUS03 Tos hiba 1 2 CAMERA OUT PUT 100 ohm GND USER_VCC N C USER_Ic For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n i c G r o u p w w w a e g i s e l ...

Page 18: ...w to Identify Monochrome and Color Camera Unit mm STC MBA5MUSB3 STC MCA5MUSB3 For More Information Please Call Aegis Electronic Group Inc 888 687 6877 Phone aegis g2 aegiselect com http www aegiselect com A e g i s E l e c t r o n i c G r o u p w w w a e g i s e l e c t c o m ...

Page 19: ...ifications 19 Ver 1 00 Revisions Rev Date Changes Note 01 April 5 2012 New document 02 April 12 2012 Corrected Maximum Frame Rate for VGA 03 April 20 2012 Added Interface Connector Specifications 1 00 October 25 2012 Full Release Document ...

Reviews: