5.2 Pulse Width Trigger Mode
In this trigger mode with positive polarity, the camera exposure starts at the rising edge of the trigger pulse and stops
at the falling edge of the trigger pulse. Therefore, when the exposure positive polarity is selected, the exposure
periods are the high states of the trigger pulse.
5.2.1 Pulse Width Trigger Mode
Note.1: The exposure time is set by the pulse width of the trigger signal. There is no FVAL output without any trigger
signal.
Exposure
time
Internal VD
exposure
Trigger signal
(Positive
)
Video out
*Note. 1
FVAL