COND SGA-A & SGA-D Manuel_EN Rev3.doc
Page 19 on 20
Rev: 03/08/2006
8.2.
Output options
±10V, ±5V, 0-10V, 0-5V, 0-20mA, 4-20mA
8.3.
Connections
Field screw terminals - 2.5mm² rising clamp.
8.4.
Enclosure
ABS case 160 x 80 x 55 sealed to IP65 fitted with 3 off cable glands.
8.5.
Controls
- Gain pot
- Offset pot
- Coarse gain switches
- Coarse offset switches
- Filter cut-off switches
- Output mode switch
8.6.
EMC Approvals
Emissions
BS EN 55011:1998
Immunity
BS EN 61000-4-2:1995 IEC 6100-4-2:1995
BS EN 61000-4-3:2002
BS EN 61000-4-4:2004
BS EN 61000-4-11:2004
Output shall not exceed the sum of uncertainties when subjected to an electric field of 10V/m over the
frequency range 80 to 600MHz
Safety/Low voltage
Directive 73/23/EEC as amended by 93/68/EEC
BS EN 61010-1:2001 IEC 61010-1:2001
8.7.
W A R R A N T Y
All COND SGA products from SENSY s.a. are warranted against defective material and workmanship for a
period of (3) three years from the date of dispatch. If the SENSY s.a. product you purchase appears to have a
defect in material or workmanship or fails during normal use within the period, please contact your Distributor,
who will assist you in resolving the problem. If it is necessary to return the product to SENSY s.a. please
include a note stating name, company, address, phone number and a detailed description of the problem.
Also, please indicate if it is a warranty repair. The sender is responsible for shipping charges, freight insurance
and proper packaging to prevent breakage in transit. SENSY s.a. warranty does not apply to defects resulting
from action of the buyer such as mishandling, improper interfacing, operation outside of design limits, improper
repair or unauthorised modification. No other warranties are expressed or implied. SENSY s.a. specifically
disclaims any implied warranties of merchantability or fitness for a specific purpose. The remedies outlined
above are the buyer’s only remedies. SENSY s.a. will not be liable for direct, indirect, special, incidental or
consequential damages whether based on the contract, tort or other legal theory. Any corrective maintenance
required after the warranty period should be performed by SENSY s.a. approved personnel only.