MOuNTING SIDE

Stay outside of the detection 

field to avoid disturbances.

Select the corresponding mounting side.

The sensor then learns its environment and automatically 

determines the detection field. Both red LEDs flash slowly and 

the 3 visible laser beams automatically light up during 30 seconds.

WITH BACKGROUND

WITHOUT BACKGROUND

The sensor memorizes the floor as reference point 
and will signal a fault in case the orientation of the 
sensor is changed (on purpose or by accident).

Adjust the 

lateral position

 of 

the detection field.

Adjust the 

tilt angle

 of the 

detection field with the hex 

key.

Lock the position

 of the 

mounting bracket to avoid 

malfunctioning in case of 

extreme vibrations.

Unlock the sensor and activate the visible laser beams.

The visible laser beams indicate approximately 
the postion of curtain C1 and limit the angle of 
the detection field.

The visible laser beams stay activated for 15 minutes 

or can be turned off the same way they were 

activated.

POSITIONING

left

right

centre

C1

C2

C3

C4

Summary of Contents for LZR-W400

Page 1: ...1 LZR W400 Laser scanner for THE SAFETY OF POWER OPERATED WINDOWS EN User s Guide for product version 0700 and more...

Page 2: ...no power power Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manu...

Page 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Page 4: ...4 VERTICAL PROTECTION HORIZONTAL PROTECTION POSSIBLE APPLICATIONS...

Page 5: ...Drill 4 holes as indicated on the mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits o...

Page 6: ...nal a fault in case the orientation of the sensor is changed on purpose or by accident Adjust the lateral position of the detection field Adjust the tilt angle of the detection field with the hex key...

Page 7: ...and adapts the detection field shape to these Objects in the detection field will be cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the de...

Page 8: ...NTS OPTIONAL FACTORY VALUES Immunity filter MIN OBJECT SIZE OUTPUT CONFIGURATION approximate values A active P passive UNCOVERED ZONE off indoor outdoor low outdoor med outdoor high indoor outdoor low...

Page 9: ...UES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote...

Page 10: ...he power supply is inverted Check cable and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step...

Page 11: ...W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V...

Page 12: ...the other relevant provisions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur November 2011 Jean Pierre Valkenberg authorized representative The complete declaration of conformity is a...

Reviews: