mode adjustment is performed with 

F

 

parameter input. “Sleep” mode adjustment is shown 

in 1.4.5. 

F

 parameter value is set in seconds (S). 

If the parameter is not equal to 

zero, signal device will not be switched "sleep” mode 

and interrogation period for parameter viewing shall be set as 

F+0,5

 seconds. Is it recom-

mended to set 5+ seconds for interrogation period; for several signaling devices with deac-
tivated "hibernation mode" in the line it is recommended to set different (+0.5 sec) interro-
gation period. 

If  the 

F

 

parameter  is  equal  to  zero,  signal device  operates with  “sleep” mode  and 

continuously interrogates the set parameter after being switched out of the “sleep” mode. 

Main  parameters  can be  viewed  and  edited in accordance with  2.4.4.1,  2.4.4.2, as 

follows: 

-

  enter transducer configuration menu; 

-

  Choose 

Sett

 menu item. 

-

  - go to 

F

 menu sub-item corresponding to required parameter, the current parame-

ter value will be displayed then; 

-

  - to edit the parameter, enter menu sub-item and type (select) new parameter val-

ue; 

-

  go to 

End

 sub-item and exit with saving changes. 

Br

 menu sub item is used for brightness adjustment. 

Brightness value ranges from 0 to 100. The more the 

Br

 value, the more the bright-

ness.  It  is  recommended  to  set  the  middle  brightness  level  value,  because  the  operation 
within the highest brightness values shall reduce the lifetime of OLED screen. 

2.4.4.2 Configuration table of viewed devices 
S.SEE

 menu sub item provides adjustment of parameters set for viewing in opera-

tion mode. 

The  main  screen  displays:  on  the  left 

–  record  reference  number  in  table,  on  the 

right - device address 

A xxx 

(picture 2.12). 

The table of devices set for viewing can be displayed and edited in accordance with 

2.4.4.1, 2.4.4.2, as follows: 

-

  enter transducer configuration menu; 

-

  scroll and select 

S.SEE

 menu item 

-

  Choose the record for editing and type new device address. 

-

  To add new record scroll to 

Add

 menu sub-item and type new device address. 

-

  go to 

End

 sub-item and exit with saving changes. 

Notes 

– 

1. Device addresses are sorted automatically by increasing number. 
2. If several equal addresses are added, only one of them will be saved. 
3. It is acceptable to set up to 128 devices for viewing. 

Table of devices set for viewing

Address of device 

set for viewing

Ordinal record

number in table

Device address

S.SEE

1.  A   1

MS-K-500-3
Address: 90.

 

Picture 2.12 

2.4.4.3 Reaction table adjustment 

Summary of Contents for SENS MS-K-500-3

Page 1: ...Research and production enterprise SENSOR SENS device Signaling device MS K 500 3 MS K 500 3S Operation Manual ...

Page 2: ... Technical specifications 3 1 3 Completeness 3 1 4 Design and operation 4 1 5 Marking 6 2 1 Safety measures notification 6 2 2 Operational limitations 6 2 4 Used items 8 3 MAINTENANCE 16 4 ROUTINE PRODUCT REPAIR 17 5 TRANSPORTATION AND STORAGE 17 6 UTILIZING 17 7 ANNEX A 18 ...

Page 3: ...he range from minus 5 up to 50 C or S3 as per GOST R 52931 2008 1 2 Technical specifications 1 2 1 Mechanical impact resistance of MS K 500 3 and MS K 500 3C signal device corresponds to V1 as per GOST R 52931 1 2 2 Water and dust ingress protection degree of the signal device is IP54 accord ing to 1 2 3 Normal functioning of the signal device can be provided if the length of power and communicati...

Page 4: ...llowing devices are installed under the signal device cover Record protection toggle 10 piezoelectric ring 6 and terminal clamp 8 designed for external circuits connec tion 1 housing 2 cover 3 cable fitting 4 looking glass 5 exterior panels 6 piezoelectric ring 7 control button 8 terminal clamp 9 installation orifice 10 record protection toggle 11 silicone gasket 12 protective sealing orifice 13 n...

Page 5: ...signal device is config ured on reaction for certain events occurrence then if the event occurred certain status byte received the indicator displays the device address designation and value of the pa rameter the indication is glowing In accordance with operator s actions the signal device in operation mode interro gates the devices connected to a SENS line and displays the parameters set by the o...

Page 6: ...f BK shall be only performed with power supply disconnected 2 2 Operational limitations 2 2 1 Use of a signaling device with mismatching power supply voltage is not al lowed 2 2 2 List of critical failures of signaling devices is given in table 2 1 Table 2 1 Failure Cause Actions A device is not op erable Mismatching power sup ply voltage Check and bring into accordance Power and or control circui...

Page 7: ...k For operation check it is required to supply power on a signal device within 1 5 se conds signal device should emit one short sound signal Then signal device shall be switched to an operation mode or a sleep mode the flashing dot or a last interrogated sensor address shall appear on the screen In case of sound signal missing or wrong indi cation on the screen signal device should be deemed as ma...

Page 8: ...king 9 2 3 5 After wiring it is required to configure signal device in accordance with a spe cific application It is necessary to check the accordance of settings recorded in configura tion data sheet for specific application and if necessary adjust the configuration Configu ration is made in accordance with cl 2 4 2 All changes must be recorded in configuration data sheet 2 3 6 Check operational ...

Page 9: ...pressure Picture 2 3 Scrolling from one parameter to the other is executed by short pressing of the signal device right button Scrolling to next device parameter view is executed by long pressing or short pressing of the right button of signal device picture 2 4 Long press inscrease value Short press select parameter back left Long press decrease value Both buttons 1 go to settings mode 2 back und...

Page 10: ...y carried out by the Manufacturer according to the purchase order data The reconfiguration of the signal device during operation may be needed if the purchase order data was incomplete or mismatching Signal device in configuration mode does not affect functionality of other devices in the line at the same time it neither interrogates transducer nor reacts on reaching of criti cal level Signal devi...

Page 11: ...o exit without saving changes indica tor boards will show message no no saving End Any changes Err S SAV Back to menu Not saved Yes No Save No changes no Not saved cancelled Er tr Device not responding YES Save Saved t Wait Picture 2 7 If the saving reading calibration etc operations requires more than 1 second the screen will display t in the main field and Wait in the information field picture 2...

Page 12: ...t d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Отступ от дна резерв SEtt d0 9 200м ПМП 201А Адрес 002 Отступ от дна резерв SEtt d0 9 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адре...

Page 13: ...peration mode End End Br Picture 2 11 List of items sub items and configuration menu parameters is listed in table 8 3 Table 2 3 N o Item sub item parameter Note Desig nation Name Des ignati on Name unit of measure ment 1 SEE Not used 2 SEtt Main configurable parameters F Interrogation period s Set in accordance with 2 4 4 3 3 Br Indicator brightness 4 S SEE Table of devices set for viewing 1 n Se...

Page 14: ...or brightness adjustment Brightness value ranges from 0 to 100 The more the Br value the more the bright ness It is recommended to set the middle brightness level value because the operation within the highest brightness values shall reduce the lifetime of OLED screen 2 4 4 2 Configuration table of viewed devices S SEE menu sub item provides adjustment of parameters set for viewing in opera tion m...

Page 15: ...t will be flashing Set the required reaction short line event is ignored long line reaction is set Scroll to End item and exit with saving changes To delete devices from table it is required to perform the following actions Choose the record subjected for removal Change the device address to 00 Scroll to End item and exit with saving changes Notes 1 Device addresses are sorted automatically by inc...

Page 16: ...interrogated by other signal device in the same time Warning If 0 address is used for configuration only one device can be con nected to the signaling device otherwise other devices can be reprogrammed by accident this can affect address and other settings i e only two devices with ad dress shall be in the line the signaling device and a device with unknown address 2 4 4 INDICATION OF ERRORS In ca...

Page 17: ...depending on operating conditions 4 ROUTINE PRODUCT REPAIR 4 1 Product repair is replacement of broken parts and units it can be carried out by organization granted to do repair of explosion proof equipment Spare parts are supplied by the manufacturer 5 TRANSPORTATION AND STORAGE 5 1 Transportation conditions shall correspond to GOST 15150 69 at medium tem perature range from 50 C to 50 C Transpor...

Page 18: ...ation conditions as to environment climatic as pects influence 1 1 2 5 1 5 2 GOST 30852 13 2002 IEC 60079 14 1996 Explosion proof electrical apparatus Part 14 Electrical installations in explosive gas atmos pheres other than mines 2 1 2 GOST 30852 16 2002 IEC 60079 17 1996 Explosion proof electrical apparatus Part 17 Inspection and maintenance of electrical installa tions in hazardous areas other ...

Page 19: ...19 NPP SENSOR LLC RUSSIA 442965 Zarechny Penza region P O Box 737 phone fax 7 841 2 65 21 00 7 841 2 65 21 55 Corr 21 10 2019 ...

Reviews: