Sensor Switch 900 Northrop Road, Wallingford, CT 06492 Phone: 1.800.PASSIVE sensorswitch.com ©2014 Acuity Brands Lighting, Inc. All rights reserved 09/19/14 IS-CM-WR-003
2 of 2
1
1
ON
OFF
ON
OFF
A.
1
3x
ON
OFF
B.
1
C.
ON
OFF
2x
LEARN
STATE
2
3x
ON
OFF
- OR -
PRESS
PRESS
ON
OFF
ON
OFF
REPEAT
STEP C FOR EACH
ADDITIONAL DEVICE
TO PAIR, THEN
PROCEED TO
STEP D.
..
G
S
PLEASE NOTE:
a) RELAY TOGGLES WHEN PAIRED WITH A NEW DEVICE.
b) WHILE IN THE LEARN STATE, THE LEDs WILL FLASH
THE PAIRED DEVICE COUNT OR GIVE RANGE WARNING
ERROR CODE (SEE SWITCH INSTRUCTION SHEET).
c) DEVICES EXIT THE LEARN STATE 2 MINS AFTER LAST
DEVICE PAIRED IF LEFT INACTIVE.
1
1
LEARN
STATE
D.
ON
OFF
1x
ON
OFF
WHILE LEDs
FLASH
1
E.
ON
OFF
PAIRING
COMPLETE
PAIRING
INSTRUCTIONS
Note:
For LED Status Indicators & Error Codes, refer to the
SPODMR WR
instruction sheet.
The following five procedures should be reviewed completely prior to setting
up wireless sensors for use with
SPODMR WR
series wireless switch units.
Note that some procedures involve using the push-button on the side of the
sensor and some involve using the push-buttons on the wall switch. If setting
up sensors for use with a different device, consult the installation guide for that
device for pairing, setting the time delay, and setting the operational mode.
Occupancy Time Delay
The length of time a paired
SPODMR WR
switch’s relay will remain closed
after the last occupied transmission from a sensor has been received.
For
PIR
sensors, the
Occupancy Time Delay
can be set from the sensor (see below
steps) or the switch (see
SPODMR WR
instruction sheet).
For
Dual Tech
sensors, the
Occupancy Time Delay
must be set from the sensor
(see below steps) and only after it is paired with the
SPODMR WR
switch.
Step 1.
Press and release sensor button 4 times
Step 2.
LED will begin flashing current setting (see selections 1-13 below)
Step 3.
To change setting, press sensor button the number of times
corresponding to the new desired setting from the below choices:
1
-
30 sec
5
- 10.0 min*
9
- 20.0 min
13
- 30.0 min
2
- 2.5 min
6
- 12.5 min
10
- 22.5 min
3
- 5.0 min
7
- 15.0 min
11
- 25.0 min
4
- 7.5 min
8
- 17.5 min
12
- 27.5 min
Step 4.
LED will flash back new setting (repeats 3 times, then exits)
Notes:
The sensor
Heartbeat Setting
will automatically be adjusted to match
this setting if under 5 minutes, and be set to 5 minutes for any higher setting.
Sensor Test Mode
Temporarily sets the
Occupancy Time Delay
on the sensor and any paired
switches to 10 seconds. Sensor LED flashes every 5 seconds indicating if
PIR occupancy was detected.
To
Enter (Exit)
test mode:
Step 1.
Press and release sensor button 6 times
Step 2.
Wait until LED begins to flash back
Step 3.
Press and release sensor button twice to Enter test mode (or once
to Exit test mode)
Notes:
1.
Sensor Test Mode
expires automatically after 10 min.
2. Dual Technology (Microphone) detections while in
Sensor Test Mode
will
not reset 10 second time delay.
3. While in
Sensor Test Mode
, the sensor
Heartbeat Setting
will be 5 seconds.
ADDITIONAL SETTINGS & MODES
Heartbeat Settings
Frequency that the sensor will transmit status information.
Step 1.
Press and release sensor button 3 times
Step 2.
LED will begin flashing current setting (see selections 1-3 below)
Step 3.
To change setting, press sensor button the number of times
corresponding to the new desired setting from the below choices:
1
- 30 sec
2
- 2.5 min
3
- 5.0 min*
Step 4.
LED will flash back new setting (repeats 3 times, then exits)
Notes:
1. It is recommended that the
Heartbeat Setting
be left alone as it will
automatically adjust if necessary with the
Occupancy Time Delay
.
2. A
Heartbeat Setting
set shorter than 5 min will reduce battery life.
3. If the
Occupancy Time Delay
is set to 10 minutes with a 5 minute sensor
Heartbeat Setting
, the “actual” time it will take for the sensor to turn the
lights off after leaving a space is between 10 and 15 minutes, depending on
how long after the last heartbeat transmission the space was vacated.
Microphone Enable/Disable (Dual Tech versions only)
Step 1.
Press and release sensor button 7 times
Step 2.
LED will begin flashing current setting (see selections 1-2 below)
Step 3.
To change setting, press sensor button the number of times
corresponding to the new desired setting from the below choices:
1
- Disable
2
- Enable*
Step 4.
LED will flash back new setting (repeats 3 times, then exits)
Unlearn (Unpair)
When a teach broadcast is received by a switch from a remote device, it is
removed from the unit’s list of learned (paired) devices.
Step 1.
Press and hold both switch buttons for 3 seconds (i.e. until button
LEDs start flashing together)
Step 2.
Press switch’s ON button 4 times
Notes:
1. While in
Unlearn Mode
, the unit will rapid flash then slow blink the
number of learned devices, and repeat.
2. Unit stays in
Unlearn Mode
for 2 minutes, or until one device is
unlearned. Press sensor button 2 times to unlearn (unpair).
3. Each time a new device is unlearned by (e.g. unpaired with) the switch,
the switch will toggle its relay.
Microphone Setback Time (Dual Tech versions only)
Maximum duration that only microphone detections (without any PIR
detections) will keep the lights on.
Step 1.
Press and release sensor button 5 times
Step 2.
LED will begin flashing current setting (see selections 1-5 below)
Step 3.
To change setting, press sensor button the number of times
corresponding to the new desired setting from the below choices:
1
- 15 min
3
- 45 min
5
- Infinite
2
- 30 min
4
- 1 hr*
Step 4.
LED will flash back new setting (repeats 3 times, then exits)
Sensor Reset
Returns sensor to original factory settings.
Step 1.
Press and release sensor button 9 times
Step 2.
LED will flash once
Step 3.
Press and release button 2 times
Step 4.
LED will flash back twice (repeats 3 times, then exits and resets)
Switch Diagnostic / Reset / Unlearn All
Provides options to reset and/or unlearn currently paired remote devices.
Also provides total paired and inactive device count information.
Step 1.
Press and hold both switch buttons for 3 seconds (i.e. until button
LEDs start flashing together)
Step 2.
Press switch’s ON button 9 times
Step 3.
LED will begin flashing current setting (see selections 1-8 below)
Step 4.
To change setting, press switch’s ON button the number of times
corresponding to the new desired setting from the below choices:
1
- Do nothing*
2
- Reset settings to factory default and unlearn all
4
- Unlearn all paired devices
5
- Reset settings to factory defaults
(without unlearning devices)
6
- Learned Device Count
7
- Inactive Sensor Count
(Paired sensors that have stopped transmitting)
8
- Unlearn All Inactive Sensors
Step 5.
LEDs will flash back current setting (repeats 3 times, then exits)
Switch Status LED Operation
Controls the normal operation of the button’s LEDs on the switch unit.
Step 1.
Press and hold both switch buttons for 3 seconds (i.e. until button
LEDs start flashing together)
Step 2.
Press switch’s ON button 11 times
Step 3.
LED will begin flashing current setting (see selections 1-2 below)
Step 4.
To change setting, press switch’s ON button the number of times
corresponding to the new desired setting from the below choices:
1
- LEDs enabled* (indicates current status of relay)
2
- LEDs disabled
Step 5.
LED will flash back current setting (repeats 3 times, then exits)
Note:
In disabled mode, LEDs will still flash when button is pushed,
device is in
Learn
or
Unlearn
mode, or device is flashing back a setting or
error code.
* Denotes factory setting
ASSEMBLED in U.S.A.
WARRANTY
5-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
TITLE 24 SYSTEM COMPONENT
Switch Learn Mode (Pairing Mode) - see diagrams A-D above
The operational state when a switch unit will accept teach broadcasts from
remote devices (e.g. sensors). Once received, the remote device will be added to
the switch unit’s list of learned (paired) devices.
Step 1.
Press and hold both switch buttons for 3 seconds (i.e. until button LEDs
start flashing together). See
Diagram A
above.
Step 2.
Press switch’s ON button 3 times (
Diagram B
above). Switch will now
be in “learn mode”
Notes:
1. While in
Switch Learn Mode
, the switch unit’s LEDs will rapid flash then slow
blink the number of learned devices, and repeat (
Diagram C
above). See switch
instruction sheet for more details regarding device count blinkout.
2. The unit will stay in
Switch Learn Mode
for 2 minutes after last device was
learned, or until ON button is pressed (
Diagram D
above).
3. Each time a new device is learned by (e.g. paired with) the switch, the switch
will toggle its relay. Wait a minumum of 4 seconds before pairing another device.
Sensor Teach Mode - see diagram C above
The operational state of a sensor when it will transmit its sensor ID to facilitate
pairing with other devices.
Step 1.
While switch is in
Switch Learn Mode,
press and release sensor button
2 times (
Diagram C
above)
Step 2.
The sensor’s LED will rapid flash when transmitting
Note:
1. Sensor resumes normal operation after one transmission is sent.
2. Use this procedure to unpair a sensor when a switch is in
Unlearn
mode.
Operational Modes
Selection of Auto-On, Manual-On, or Predictive w/ Expiration operating modes.
Step 1.
Press and hold both switch buttons for 3 seconds (i.e. until button LEDs
start flashing together)
Step 2.
Press switch’s ON button 5 times
Step 3.
LED will begin flashing current setting (see selections 1-3 below)
Step 4.
To change setting, press switch’s ON button the number of times
corresponding to the new desired setting from the below choices:
1
- Auto-On:
Load will automatically turn on when occupied and off when vacant.
Pressing OFF will turn the load off and disable occupancy detection until ON
is pressed.
2
- Manual-On/Vacancy (*default for -SA option units):
Sensor functions as a vacancy detector, turning load off after occupancy is
no longer detected. Load must be turned on manually by pressing ON
button each time the room is entered. After the sensor times out, there is
a 10 second grace period in which detection of occupancy will automatically
turn the load back on.
3
- Predictive Mode w/ Expiration (*default for non-SA units):
Load will automatically turn on when occupied and off when vacant. Load
can be overridden to off by pressing OFF button. The load will remain off
if the room remains occupied. However, after the room becomes vacant, the
switch will revert back to automatic on/off operation after
Occupancy Time
Delay
expires.
Step 5.
Switch’s
LED will flash back current setting (repeats 3 times, then exits)
ON
OFF
ON
OFF
ON
OFF
SETUP INSTRUCTIONS
ON
OFF
ON
OFF
REPEAT
STEP C FOR EACH
ADDITIONAL DEVICE
TO PAIR, THEN
PROCEED TO
STEP D.
..
G
S
PLEASE NOTE:
a) RELAY TOGGLES WHEN PAIRED WITH A NEW DEVICE.
b) WHILE IN THE LEARN STATE, THE LEDs WILL FLASH
THE PAIRED DEVICE COUNT OR GIVE RANGE WARNING
ERROR CODE (SEE SWITCH INSTRUCTION SHEET).
c) DEVICES EXIT THE LEARN STATE 2 MINS AFTER LAST
DEVICE PAIRED IF LEFT INACTIVE.
ON
OFF
ON
OFF