background image

AirDistSys 5000

 

 

14 – Operator’s Manual

 

5

5

.

.

 

 

 

 

S

S

O

O

F

F

T

T

W

W

A

A

R

R

E

E

 

 

A

A

N

N

D

D

 

 

D

D

R

R

I

I

V

V

E

E

R

R

 

 

I

I

N

N

S

S

T

T

A

A

L

L

L

L

A

A

T

T

I

I

O

O

N

N

 

 

 

 

 

1.

 

Power on your computer and boot to Windows.

 

 

2.

 

Insert the CD-ROM in your CD drive, choose setup.exe in folder AirDistSys_Inst and run. 

3.

 

Follow the on-screen instructions. 

4.

 

The driver for new device  will be installed automatically after finishing the installation. In the case of 
trouble it is possible to install the driver into the following way: 

 Option 1 

 

select  SensoUSB  DriverInstaller  icon  from  SENSOR  Electronic  folder  located  in  Program  Menu 
Folder  or  click  it  on  the  Desktop  Panel  (the  SensoUSB  DriverInstaller.exe  file  is  also  in 
SensoUSB_driver folder on the CD-ROM. 

 

locate the USB port and plug in the device (SensoConnect USB or SensoBee USB). 

 

Windows automatically will detect the new device and will install the software for the detected USB 
device. 

 

 

Option 2 

 

locate the USB port and plug in the device (SensoConnect USB or SensoBee USB). 

 

Windows  will detect the new device and  will initiate the Found New Hardware Wizard prompting 
you to install the software for the detected USB device. 

 

select the “Specify a location” and choose the correct path. Enter E:\SensoUSB_driver\. The “E” is 
the Disk that Package CD put in. Click “OK” to start the search. 

 

once Windows finds the correct driver, click “Next” to install the driver. 

5.

 

To  verify  whether  the  device  is  properly  installed  and  to  determine  the  COM  port  assignment  for  the 
device follow the steps: 

 

 

click “Settings” and “Control Panel”, and then double click on the “System” icon.  

 

once the System Properties window is displayed select the “Device Manager” button.  

 

double-click on Ports (COM &LPT).  

 

if the device is correctly installed, you should now see the USB device listing and the assigned COM 
port. 

6.

 

If you need to assign the COM port name to another Port Number: 

 

double-click on the USB device to view the properties 

 

once the properties window opens click on the Port Settings tab and select the advanced button 

 

when the Advanced Settings dialog box appears on the screen, click on the COM Port Number drop 
down the box to check what other port number are available 

 

try to reassign COM port to a unused port number 

 

click OK when finished. 

 

 

 

6

6

.

.

 

 

 

 

D

D

E

E

S

S

C

C

R

R

I

I

P

P

T

T

I

I

O

O

N

N

 

 

O

O

F

F

 

 

T

T

H

H

E

E

 

 

P

P

R

R

O

O

G

G

R

R

A

A

M

M

 

 

 

  

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

 

 

a

a

n

n

d

d

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

m

m

e

e

n

n

t

t

s

s

 

 

 

 

 

The AirDistSys 5000 program makes possible for: 
-  automatic scanning of the configuration of the measuring system 
-  calculating  average  temperature,  average  and  standard  deviation  of  air  speed,  turbulence  intensity, 

draught  rate  (as  recommended  in  ISO  Standard  7730,  ISO  standard  7726,  EN  15251,  ASHRAE 
Standard 113) 

-  automatic compensation for the impact of changes in the barometric pressure 
-  logging and reporting all data in a PC computer 

 

Program requirements: 
-

 

operating system: Microsoft Windows XP, Vista, 7, 8, 10 

-

 

minimal monitor resolution: 1024x600 pixels 

-

 

size of text and other elements in Windows: default 100% 

Summary of Contents for AirDistSys 5000

Page 1: ...ectronic pl office sensor electronic pl PL 44 100 Gliwice Poland Edition 19 4 A Ai ir r D Di is st tr ri ib bu ut ti io on n M Me ea as su ur ri in ng g S Sy ys st te em m A Ai ir rD Di is st tS Sy ys s 5 50 00 00 0 O Op pe er ra at to or r s s M Ma an nu ua al l ...

Page 2: ...nd the PC for data logging the built in TCP IP connection enables transfer data from server AirDistSys program to different computers by the networks the DataSocket technology compatible with LabView platform provides converting measurement data into a stream of bytes that is sent across the network to another application Optionally the system may be equipped with transducer SensoBar 5301 which ma...

Page 3: ...ic 1 Sens oAnemo trans du ce r e le c t ron ic 1 Sens oAnemo trans du ce r e le c t ron ic 1 Sens oAnemo trans du ce r e le c t ron ic 1 max 8 max 8 SensoConnect USB interface Se nsoBee U S B recei v er e l e ctro n ic 60m SensoBee t ra ns m itter e l e ctr o n i c Sens oBee transmi t te r el e ctro ni c SensoCables 5601 length 0 75m SensoCables 5601 length 0 75m max 60m SensoBee transmitter Power...

Page 4: ...s shape is cylindrical The temperature sensor measures temperature of the ambient air The two sensors are vacuum covered with a special aluminium coating that increases their resistance to contamination and decreases the effect of thermal radiation on the accuracy of velocity measurement Both sensors can be also protected against mechanical damage using a openwork basket 4 made with wire circles I...

Page 5: ...f 0 f 30 f 60 f 90 f 120 f 150 f 180 f 150 f 120 Directional sensitivity vs yaw angle reference mean velocity of 1 m s 0 0 2 0 4 0 6 0 8 1 w 90 w 60 w 30 w 0 w 30 w 60 w 90 w 120 w 150 w 180 w 150 w 120 Directional sensitivity vs roll angle reference mean velocity of 1 m s 0 04 0 03 0 02 0 01 0 0 01 0 02 0 0 1 0 2 0 3 0 4 0 5 Deviation m s Velocity m s Impact of natural convection horizontal flow ...

Page 6: ...n between the transducers 7 Turn on the power supply The power led on the casing should blink firstly for a few seconds and next will remain ON If the led blinks permanently it means that is the error The case of the error might to be too low voltage of power supply caused for example by unloaded batteries Remarks 1 The speed sensor 1 must be protected during transport by the shielding tube 3 Note...

Page 7: ...entilation in buildings Instrumentation requirements for air velocity measurements in ventilated spaces 2002 European Committee for Standardization Brussels B B S Se en ns so oD DA AC Co on n c co on nv ve er rt te er r SensoDACon converter series 5400 allows to change a digital signal from Sensoanemo transducer socket RJ45 on the analog signal of temperature and velocity output terminal block The...

Page 8: ...f humidity 4s interface port RS485 baud rate 115000 bps power supply 3 3 9 VDC power consumption 6mA economy mode 1mA Connecting to the measuring system The SensoBar 5301transducer can be connected at any place of the RS485 bus to the measuring system for example to SensoAnemo transducer either SensoBee wire less transmitter or SensoBox adapter using the Cable adapter 1W 2G or another see figure b...

Page 9: ...latch for mounting it in the DIN rail Connecting to the measuring system Remark Pay attention that the power supply adapter should have the voltage polarity on the plug compatible with power socket in the casing out F F S Se en ns so oB Be ee e w wi ir re e l le es ss s t tr ra an ns sm mi it tt te er r The SensoBee transmitter contains an RF module for wire less data transmission The RF module op...

Page 10: ... connected to USB port therefore it doesn t require the use of external power supply adapter The SensoBeeUSB can also be used for wired data transmission see example D or F in the chapter 2 In this case you should connect to the RJ45 socket one end of the connecting cable and the other end depending on the configuration either the SensoBox adapter or SensoBee wire less transmitter either directly ...

Page 11: ... capacity Capacity due to reduced efficiency when converting from battery voltage 3 6 V to output voltage 5V theoretical capacity of the battery is 10000 13000mAh Remarks 1 Turn off the PowerBank by disconnecting the power cable when you are finished working Otherwise this may lead to rapid discharge of the battery 2 Charge and discharge the device once every 3 months if it is not used for a longe...

Page 12: ...n the photos below Attention should be paid to the pipes D1 D3 turn in the order corresponding to the incisions ie D1 pipe single to the D2 dual and D2 to D3 pipe triple D1 pipe should be inserted to the base of the tripod and locked by the knob Then place the grips for fastening the measuring transducers and DIN grips for the accessories and lock them using the knobs C C S St ta an nd da ar rd d ...

Page 13: ...o ou un nt te ed d g gr ri ip p The rail mounted grip enables to mount the devices equipped with latch for DIN rail so as SensoBar transducer SensoBee wire less receiver SensoBox adapter or PowerBank You can mount it on a tripod in two positions vertical or horizontal ...

Page 14: ...ce is properly installed and to determine the COM port assignment for the device follow the steps click Settings and Control Panel and then double click on the System icon once the System Properties window is displayed select the Device Manager button double click on Ports COM LPT if the device is correctly installed you should now see the USB device listing and the assigned COM port 6 If you need...

Page 15: ...nt results Averaging is continuous i e the oldest result is being replaced with the youngest result in the cycle of averaging Averaging Time is independent from Interval Time which is a parameter of logging Logged Data Only logged results are displayed according to logging parameters Interval Time and Logging Time Data Graph Results are shown as vertical strips Numbers of a probe are presented on ...

Page 16: ... io on n When you use this protocol the program communicates with the DataSocket Server You must provide a named tag for the data which is appended to the URL The data connection uses the named tag to address a particular data item on a DataSocket Server To use this protocol you must run a DataSocket Server In order to enable or disable the DataSocket connection select DataSocket from the menu ite...

Page 17: ... Data Client is available in the Program Menu Folder SENSOR Electronic Examples C Ca al lc cu ul la at ti io on n o of f R Re es su ul lt ts s Air temperature average speed and standard deviation of speed are calculated as shown in the below figure The sampling rate is a constant and is 8 Hz regardless of the selected mode to display the results To increase the bandwidth of the communications the ...

Page 18: ...s results are shown on the charts with delayed 1s D Da at ta aS So oc ck ke et t C Co on nn ne ec ct ti io on n When you use this protocol the program communicates with the DataSocket Server You must provide a named tag for the data which is appended to the URL The data connection uses the named tag to address a particular data item on a DataSocket Server To use this protocol you must run a DataSo...

Page 19: ...TCP connection The part of string with column headers is ended by CR carriage return element On the end of result string is EOL Example data string with results 23 1 TAB 23 2 TAB 22 9 EOL Example data string with column headers ta degC TAB tnw degC TAB tg degC CR 23 1 TAB 23 2 TAB 22 9 EOL The example of TCP Data Client is available in the Program Menu Folder SENSOR Electronic Examples 7 7 G GU UA...

Reviews: