AirDistSys 5000
14 – Operator’s Manual
5
5
.
.
S
S
O
O
F
F
T
T
W
W
A
A
R
R
E
E
A
A
N
N
D
D
D
D
R
R
I
I
V
V
E
E
R
R
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
1.
Power on your computer and boot to Windows.
2.
Insert the CD-ROM in your CD drive, choose setup.exe in folder AirDistSys_Inst and run.
3.
Follow the on-screen instructions.
4.
The driver for new device will be installed automatically after finishing the installation. In the case of
trouble it is possible to install the driver into the following way:
Option 1
select SensoUSB DriverInstaller icon from SENSOR Electronic folder located in Program Menu
Folder or click it on the Desktop Panel (the SensoUSB DriverInstaller.exe file is also in
SensoUSB_driver folder on the CD-ROM.
locate the USB port and plug in the device (SensoConnect USB or SensoBee USB).
Windows automatically will detect the new device and will install the software for the detected USB
device.
Option 2
locate the USB port and plug in the device (SensoConnect USB or SensoBee USB).
Windows will detect the new device and will initiate the Found New Hardware Wizard prompting
you to install the software for the detected USB device.
select the “Specify a location” and choose the correct path. Enter E:\SensoUSB_driver\. The “E” is
the Disk that Package CD put in. Click “OK” to start the search.
once Windows finds the correct driver, click “Next” to install the driver.
5.
To verify whether the device is properly installed and to determine the COM port assignment for the
device follow the steps:
click “Settings” and “Control Panel”, and then double click on the “System” icon.
once the System Properties window is displayed select the “Device Manager” button.
double-click on Ports (COM &LPT).
if the device is correctly installed, you should now see the USB device listing and the assigned COM
port.
6.
If you need to assign the COM port name to another Port Number:
double-click on the USB device to view the properties
once the properties window opens click on the Port Settings tab and select the advanced button
when the Advanced Settings dialog box appears on the screen, click on the COM Port Number drop
down the box to check what other port number are available
try to reassign COM port to a unused port number
click OK when finished.
6
6
.
.
D
D
E
E
S
S
C
C
R
R
I
I
P
P
T
T
I
I
O
O
N
N
O
O
F
F
T
T
H
H
E
E
P
P
R
R
O
O
G
G
R
R
A
A
M
M
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
a
a
n
n
d
d
R
R
e
e
q
q
u
u
i
i
r
r
e
e
m
m
e
e
n
n
t
t
s
s
The AirDistSys 5000 program makes possible for:
- automatic scanning of the configuration of the measuring system
- calculating average temperature, average and standard deviation of air speed, turbulence intensity,
draught rate (as recommended in ISO Standard 7730, ISO standard 7726, EN 15251, ASHRAE
Standard 113)
- automatic compensation for the impact of changes in the barometric pressure
- logging and reporting all data in a PC computer
Program requirements:
-
operating system: Microsoft Windows XP, Vista, 7, 8, 10
-
minimal monitor resolution: 1024x600 pixels
-
size of text and other elements in Windows: default 100%