sensonor STIM210 User Manual Download Page 15

 

USER MANUAL

 

EvaluationTools

 

STIM210 Evaluation Kit - USB

 

 

 
DOK452 rev.0                                        

   15/20                                                              2020 

 

 

7.3 

Normal mode panel descriptions 

 

 
Table 2: Normal mode panel descriptions. 

Panel unit 

Functionality and description 

Connect to HW 

Connects to interface hardware. Opens COM port according to settings specified in 
active parameter file 

LED 

Indicator for hardware connection. A GREEN light indicates the COM port is 
opened 

Disconnect from HW 

Disconnects from interface hardware. Closes the COM port 

Initiate power-on sequence 
switch 

Toggles supply voltage if configured with an external power supply. Controls 
certain functions of the PC software 

Device box 

Device number (and corresponding COM port) according to active parameter file. 
Selects which gyro module is activated for datagram requests in Normal mode, 
Service mode operations and measurements in Measure panel. Does not apply for 
Logging panel 

Reset device button 

Resets the gyro module

. Sends reset command (‘R’) 

Request config DG button 

Sends command (‘C’) to receive configuration datagram 

Request identity DG button 

Sends command (‘N’) to receive part number datagram 

Request serial# DG button 

Sends command (‘I’) to receive serial number datagram 

Request Ext status button 

Sends command (‘E’) to receive extended error information datagram 

Response window 

Displays response to special datagram requests ('C', 'N' and 

‘I’ datagrams) 

 
 

7.4 

Service mode panel descriptions 

 
Service mode is used for gyro module configuration. 
 
Service mode is entered by clicking on the Service mode tab next to the Normal mode tab after the gyro module has 
been powered up. Service mode usage, functionalities and descriptions are listed in Table 3. Exit from Service mode 
to Normal mode by selecting one of the other panel tabs (Normal, Logging, Service or Parameter panel tab). 
 
Note: Changes made for the gyro module in Service mode are only stored permanently in flash memory when the 
save command (‘s’) subsequently is sent to the gyro module. 
 

 
Table 3: Service mode panel descriptions. 

Panel unit 

Functionality and description 

Available commands window 

Shows a list of available commands. See product datasheet for details 

Complete command window 

Contains the complete command to be sent. The command is auto-completed by 
the software during usage of the listings in the Available commands window. Left 
click inside the Complete command window brings up a list of previously sent 
commands. Right click enables manual command entry 

Send command button 

Sends command to the gyro module 

Active device indicator 

Indicates active gyro module. Corresponding COM port is specified in the active 
parameter file 

Command response window 

Shows the responses to commands from the gyro module. See product datasheet 
for details 

Erase button 

Clears the content of the command response window 

Save button 

Saves the content of the command response window to a text file with a date and 
time tag 

7.5 

Measure panel descriptions 

 

 
Table 4: Measure panel descriptions. 

Panel unit 

Functionality and description 

Measure button 

Starts a measurement series 

Samples box 

Defines the number of samples to be collected (max 50 MS) 

Summary of Contents for STIM210

Page 1: ...ON OF SERIAL DRIVER 4 4 3 INSTALLATION OF PC SOFTWARE 6 5 CONNECTING THE STIM TO YOUR PC 6 6 USING PC SOFTWARE 7 7 INTRODUCTION TO PC SOFTWARE 12 7 1 PANELS OVERVIEW 12 7 1 1 Service mode panel 12 7 1...

Page 2: ...p criteria for measurements available Manually No of samples or Time elapsed Measurements of up to 4 gyro modules simultaneously supported requires additional cables depending on the type of evaluatio...

Page 3: ...ationTools STIM210 Evaluation Kit USB DOK452 rev 0 3 20 2020 4 Getting started Preparing your system involves the following steps FTDI Serial Driver installation Serial Driver verification EVK PC Soft...

Page 4: ...itable driver In the event that no automatic installation takes place please refer to the set up guide from FTDI http www ftdichip com Support Documents InstallGuides htm 4 2 Verification and configur...

Page 5: ...IM210 Evaluation Kit USB DOK452 rev 0 5 20 2020 Select Advanced from the Port Setting tab Set the Receive Bytes and Transmit Bytes settings to 256 Press OK twice The computer may have to be restarted...

Page 6: ...by running setup exe found on the included memory stick Follow the on screen instructions to complete the installation The PC software also can be downloaded from the Sensonor support site Check this...

Page 7: ...nistrator rights Figure 3 Starting PC software from Windows start menu 2 A pop up box appears asking for a parameter INI file Select the INI file available in the installation folder by default and pr...

Page 8: ...NUAL EvaluationTools STIM210 Evaluation Kit USB DOK452 rev 0 8 20 2020 Figure 5 Welcome message and software registration 4 The Normal mode panel is shown Figure 6 Normal mode panel after selecting IN...

Page 9: ...o this by double clicking on the value and enter correct value The default password to edit is stim Figure 7 Edit the INI file in order to verify correct COM port settings 6 Go back to Normal mode pan...

Page 10: ...at this point The pop up message asking for confirmation of bitrate appears Press OK Figure 9 Confirm bitrate 8 A pop up message telling Connect power cable to voltage supply and then press OK to con...

Page 11: ...rriving from device n indicates that data is received from the gyro module s Verify the communication to module by clicking on the Request serial DG button An example of such a result is shown in Figu...

Page 12: ...ion Kit USB DOK452 rev 0 12 20 2020 7 Introduction to PC software 7 1 Panels overview In addition to the panel already shown Normal mode and Parameters panel other panels are also available 7 1 1 Serv...

Page 13: ...USER MANUAL EvaluationTools STIM210 Evaluation Kit USB DOK452 rev 0 13 20 2020 7 1 2 Measure panel Figure 13 Measure panel 7 1 3 Logging panel Figure 14 Logging panel for saving data to file...

Page 14: ...r file For loading an existing INI file File Save parameter file as To save current parameter settings with a new file name File Print parameters For printing the current Parameters content on the def...

Page 15: ...mode is entered by clicking on the Service mode tab next to the Normal mode tab after the gyro module has been powered up Service mode usage functionalities and descriptions are listed in Table 3 Exi...

Page 16: ...Rate Incremental Angle etc DG type box Displays the type of datagram received Save to disk icon Saves the plot to a JPG file Print icon Prints a picture of the plot to the default printer 1 1 icon Res...

Page 17: ...rage box Used for specifying how many samples should be averaged before saving the averaged value to file If values is 1 no averaging is done Time elapsed Shows the time elapsed since start of test Sa...

Page 18: ...2 Defining which COM port to assigned to gyro module 2 RS422 Bitrate bit s RS422 bit rate selection RS422 Stopbit 1 or 2 Default is 1 RS422 parity None odd or even Default is None External Hardware Th...

Page 19: ...sent 8 No configuration datagram received Even after retries the expected datagram is not received as response to command sent 9 No serial number datagram received Even after reties the expected datag...

Page 20: ...l edit mode is ended 22 You are about to change the RS422 bit rate If are you using the USB kit hardware provided by Sensonor please notice that you will not be able to communicate with the device if...

Reviews: