Save data to file from measure panel:
An example of a result file is shown in Figure 25, for a standard datagram measurement series of device # 1. A
description of each of its column of data is found in Table 4.
Figure 25: Result file example
Table 4: Result file example. (Standard datagram content written to file.)
DG-type
Col. #
Heading
Comments
S
tan
da
rd
1
Time[s]
Time in seconds
2
X[°/s] or X[°]
Gyro signal X-axis
3
Y[°/s] or Y[°]
Gyro signal Y-axis
4
Z[°/s] or Z[°]
Gyro signal Z-axis
5
STS
Status-byte
6
RxCRC
Received CRC
7
CalCRC
Calculated CRC
8
DG_ID
Datagram identifier
7.6
Logging panel descriptions
Table 5: Logging panel descriptions
Panel unit
Functionality and description
Start button
Starts data logging
Stop button
Stops data logging
Stop criteria slide
User selections between “manually”, “no of samples” and “Time
elapsed” for stopping a measurement series
Samples box
In use when defining a series length
with “no of samples”
Time elapsed
Shows the real time for the test running
Samples acq.
Shows number of samples acquired
CRC_errors
Shows number of CRC errors (normally 0, otherwise the user should
consider to reject results data in any analysis)
Resynch’s
Increments from 0 to a number if any re-synchronisations are needed in
order to re-establish data collections from module
Log to file capability:
Quad core processor is recommended when measuring on two gyro modules simultaneously
The size of the log file is only limited by the free memory of the hard disk(s) in use
The path for result file storage is defined in the active parameter file
The program should be run as administrator to ensure the necessary rights to establish result files