Software Installation Instructions 

TTM Remote Site Server

 

 

©

 SENSITECH INC 

REV A  

9/6/2005 

 

 

13

 

 

Appendix A  RfNetCfg.xml  

 

<

RfNetCfg

>

 

 

 

<

maxthreads

>

3

</

maxthreads

>

  

<!--

 

max number of monitors to be dowloaded at a time

-->

 

 

<!--

 

Gateway id upto 12 digits must be numeric this is the location id 

transmitted to the omegarfs 

 

-->

 

 

<!--

 

Gateway GwNameOrIP IP address or machine name of gateway 

 

-->

 

 

<!--

 

Gateway TstConnIntvl interval in seconds to check gateway 

connection 

-->

 

 

<!--

 

Gateway ReConnIntvl interval in seconds to retry connection to 

gateway 

-->

 

 

<!--

 

Gateway id="1965" GwNameOrIP="172.16.24.92" TstConnIntvl="900" 

ReConnIntvl="60" 

-->

 

 

 

 

<

Gateway

 

id

="

1965

"

 GwNameOrIP

="

192.168.1.92

"

 TstConnIntvl

="

900

"

 

ReConnIntvl

="

60

" />

  

 

 

<

Repeater

 

HwId

="

3781220487940567

"

 GwBoundTo

="

192.168.1.92

" />

  

 

 

<

Repeater

 

HwId

="

3781220487940339

"

 GwBoundTo

="

192.168.1.92

" />

  

 

 

<

ForceAcquireInterval

>

1800

</

ForceAcquireInterval

>

  

<!--

 

Interval in seconds to reacquire all omegarfs 

-->

 

 

 

 

<

Snmp

 

MgrNameOrIP

="

192.168.1.47

"

 MgrPort

="

162

"

 NotifyLnkDwn

="

true

"

 

NotifyLnkUp

="

true

"

 enterprise

="

1.3.6.1.4.1.23684.6.1.0

"

 

GwDwnOid

="

1.3.6.1.4.1.23684.6.1.0.5.0

"

 GwUpOid

="

1.3.6.1.4.1.23684.6.1.0.6.0

"

 

RptrDwnOid

="

1.3.6.1.4.1.23684.6.1.0.7.0

"

 

RptrUpOid

="

1.3.6.1.4.1.23684.6.1.0.8.0

" />

  

 

 

</

RfNetCfg

>

 

 

Summary of Contents for TempTale RF

Page 1: ...ch could void the users authority to operate the equipment RADIO AND TELEVISION INTERFERENCE NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursua...

Page 2: ...ter Signpost with a GLN and set Modes 6 Signpost Repeater commands 7 LED Patterns 9 Section 2 Software Installation Instructions TTM Remote Site Server 10 System Requirements 10 Configuration Values R...

Page 3: ...MHz band the following channel is used 869 850 MHz The RF signal used is a narrow band transmission that transmits power at 2 dBm for the monitors and 0dBm for the Infrastructure Gateway Repeaters and...

Page 4: ...f the TempTale RF infrastructure Equipment RS232 Serial cable 1 TTL Converter 1 RJ45 Ethernet crossover cable 1 TTRF Gateway 1 Repeater 1 Gateway Power Adaptor 1 Repeater Power Adaptor 1 PC with Start...

Page 5: ...er Terminal Name i e gateway then press OK 10 In the Connect using dropdown select COM1 then press OK 11 Set values to Bits per second 19200 Data bits 8 Parity none Stop bits 1 Flow control none then...

Page 6: ...r Signpost with a GLN and set Modes 1 Make sure power is off on the TTRF Repeater Signpost 2 Open up the front panel of the TTRF Repeater Signpost and attach the Serial 10 pin cable to the 10 pin conn...

Page 7: ...ignpost about 20 seconds to reboot After a reboot you will not see any prompt until you again press Enter 12 To display the current configuration use the d command For example d Enter Searching for a...

Page 8: ...ear the GLN and turn the Signpost back in to a Repeater Signpost use the c command followed by the e command 18 You can also configure the Signpost to be a Repeater Signpost use the r command followed...

Page 9: ...ond interval blinks indicating channel n Note will be 1 flash for channel 1 1 second off The TTRF Repeater Signpost s Red LED DS4 will blink the following pattern 0 33 second blink rate Functioning as...

Page 10: ...er is running on Application ID of monitors being used in application Location of rfupload folder where data files are to be sent Media TempTale Manager Remote Site Server ver 5 1 Installation The Fol...

Page 11: ...of the IP Address or network machine name of the machine running the SNMP Manager i e HP Open View 13 Verify the MgrPort is set to 162 Note Value can only be 161 or 162 14 Verify that if SNMP is being...

Page 12: ...der the local SYSTEM user account which will probably not have authorization to use the proxy Instead you ll probably need to setup the service to run under some domain user account that has the appro...

Page 13: ...onds to retry connection to gateway Gateway id 1965 GwNameOrIP 172 16 24 92 TstConnIntvl 900 ReConnIntvl 60 Gateway id 1965 GwNameOrIP 192 168 1 92 TstConnIntvl 900 ReConnIntvl 60 Repeater HwId 378122...

Page 14: ...ownload true to download monitor false won t start true to start monitor false won t stop true to stop monitor false won t restart reactivates monitor current config and start it false won t mindeptim...

Page 15: ...tomer config file appSettings configuration Appendix D SendDataToCentralSite xml xml version 1 0 encoding utf 8 configuration appSettings add key FlowDefaultCredentialsToWebProxy value false add key T...

Reviews: