background image

 

Instruction Manual

For use with methane gas only.

Read and understand instructions before use.

Patented

SENSIT

®

 IRED

I N F R A R E D   E T H A N E   D E T E C TO R

851 Transport Drive

Valparaiso, IN 46383-8432

MADE IN USA

SENSIT Technologies 

is in compliance with ISO 9001:2008

Phone:  888 4SENSIT

 

888 473 6748

  

219 465 2700

Fax:    219 465 2701

 www.gasleaksensors.com

Summary of Contents for IRED

Page 1: ...instructions before use Patented SENSIT IRED INFRARED ETHANE DETECTOR 851 Transport Drive Valparaiso IN 46383 8432 MADE IN USA SENSIT Technologies is in compliance with ISO 9001 2008 Phone 888 4SENSI...

Page 2: ...to use Always start the IRED in an area known to be gas free Tampering with this product may void the warranty Use only Sensit Technologies approved parts and accessories Never use an instrument known...

Page 3: ...cription 4 Parts and Accessories 5 Product Specifications 6 Product Features 6 Electronic Features 7 Display Features 8 Housing Features 9 Filters 10 Field Operations 11 12 Bump Test 13 Calibration 14...

Page 4: ...an output that is changed when certain gases absorb the light output The filter only allows specific light wavelengths to be monitored and measured The concentration of gas is proportional to the amo...

Page 5: ...Part 873 00024 Survey Probe Filter Blue 1 Filter Part 360 00064 SENSIT IRED Calibration Kit IRED Calibration Kit Part 881 00100 Kit includes 1 Regulator 1 Cal Adapter 1 100pm Ethane Nitrogen 58L SENS...

Page 6: ...ic Sensor Specifications IR Sensor Method Advanced Infrared Absorption Spectroscopy Detection Range 250ppb 1000ppm Warm up 30 min Calibration required 3 months Product Features The IRED is constructed...

Page 7: ...ghting IR communication port LCD Button Operation The Sensit IRED is operated with the use of three buttons below the display They are labeled A B C The A button Activates Deactivates the instrument A...

Page 8: ...once for manual data save GPS Connected GPS enabled not connected 8 Display Features The display provides all information including Gas concentration in PPB and PPM Battery voltage status Pump Status...

Page 9: ...taining screws Charge Complete Green Charging Red Status Yellow Charger Connection The battery pack has LED s to indicate charge status Charging should only be performed in an area know to be free of...

Page 10: ...r shoulder strap attachment Clips on the strap will attach securely Hydrophobic Filter Assembly WARNING Do not operate without proper filter Damage may occur to the pump and other internal parts Only...

Page 11: ...nd Time d Warm up is indicated PLEASE WAIT with a 600 second countdown timer The countdown timer will begin after an initial warm up of 5 10 minutes e Calibration due date indicating when calibration...

Page 12: ...imer c The measuring of ethane is indicated by the MEASUREMENT heading and the ppb ppm readings During a measurement 4 consecutive 10 second readings are taken Each reading is averaged over the 10 sec...

Page 13: ...stable reading must occur before the process automatically continues 5 If the reading is not stable the zeroing process will automatically re initiate indicated by a RE ZEROING message This process r...

Page 14: ...stable reading must occur before the process automatically continues 5 If the reading is not stable the zeroing process will automatically re initiate indicated by a RE ZEROING message This process r...

Page 15: ...mplemented 10 ALARM PPM This is not implemented 11 PURGE TIME Time in Sec unit should purge system before shutting down 12 ERASE BUMP LOG Allows you to erase bump logs 13 ERASE CAL LOG Allows you to e...

Page 16: ...Proof of purchase may be requireds before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies au...

Reviews: