38
39
ELECTRICAL ACCESSORIES
GZL 1019 A1
Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 1 m.
GZL 1019 A5
Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 5 m.
GZL 1019 A10
Connection cable
For connecting the radiator to the transmitters SI 1013,
SI 29-5 or SI 1029. Length 10 m.
GZV 1019
BNC coupler
For connecting two connection cables GZL 1019 A1, -5, -10.
N.B.: „INFRA-RED
If you consider using a transmission system with high power IR radiators
PLANNING BROCHURE“
SZI 1029 the „Infra-red Planning Brochure“ from Sennheiser is available.
FROM SENNHEISER
Besides in-depth information on infra-red transmission technology it
contains application examples and lists with combinations and overviews
for infra-red system planning.
Since we are continually trying to improve our products it may happen
that some technical alterations are made on the described products after
these operating instructions have gone to press. We apologise for any
inconvenience.
TECHNICAL SPECIFICATIONS
SZI 1029 (SZI 1029-10)
Number of radiator diodes
144 (288)
Approximate radiating power
5 W (10 W)
Wavelength of radiated
infra-red light approx.
880 nm
Carrier frequency range
30 kHz - 6 MHz
IR input
50 mV - 3 V / approx. 5 k
Ω
Input/output connections
BNC sockets
Switching treshold for
automatic on/off function
50 mV
Operating voltage
...-120
85 - 265 V
±
10 %, 50 - 60 Hz
...-EU
85 - 265 V
±
10 %, 50 - 60 Hz
...-UK
85 - 265 V
±
10 %, 50 - 60 Hz
...-24
24 V min., ideally 25 - 35 V DC
Current consumption ...-120
approx. 610 mA (1A) with 120 V
...-EU approx. 350 mA (700 mA) with 230 V
...-UK approx. 350 mA (700 mA) with 240 V
...-24
approx. 1.6 A (3.2 A) with 24 V DC
Stand-by
60 mA max.
Mains fuse for 120/230/240 V
2 A, anti-surge type
in the IEC mains socket
Fuse for 24 V
DC 2 A, anti-surge type
Dimensions in mm
250 x 180 x 80 (250 x 288 x 80)
Weight
approx. 2.1 kg (approx. 3 kg)
Supply schedule
1 radiator
1 mains cable (2.5 m)
UL-No. (only for 120 volt
USA version)
to be advised
Summary of Contents for SZI 1029
Page 57: ...112 113 ...
Page 58: ...114 115 ...