background image

Instruction Manual

SKP 100

Summary of Contents for SKP 100 G3

Page 1: ...Instruction Manual SKP 100...

Page 2: ...vating the lock mode temporarily 9 Muting the audio signal or deactivating the RF signal 9 Selecting a standard display 10 Using the operating menu 11 The buttons 11 Overview of the operating menu 11...

Page 3: ...titutions may result in fire electric shock or other hazards Refer all servicing to qualified service personnel Servicing is required if the device has been damaged in any way liquid has been spilled...

Page 4: ...ady for immediate use after switch on several transmission systems can be operated simultaneously on the preset frequencies without causing intermodulation interference The frequency bank system The p...

Page 5: ...informa tion sheet can be downloaded from the SKP 100 G3 product page on our website at www sennheiser com The frequency bank U allows you to freely select and store transmission frequencies It might...

Page 6: ...le unbalanced Mechanical locking ring of XLR 3 socket Infra red interface Display panel backlit in orange UP button DOWN button Operation and battery status indicator red LED lit ON flashing LOW BATTE...

Page 7: ...econds Display Meaning Audio level AF Modulation of the plug on transmitter with peak hold function Frequency Current transmission frequency Name User selectable name Transmission icon RF signal is be...

Page 8: ...nt The battery compartment cover locks into place with an audible click Charging the accupack Remove the BA 2015 accupack optional accessory Insert the BA 2015 accupack into the L 2015 charger accupac...

Page 9: ...panel The transmission icon is displayed You can switch the plug on transmitter on and deactivate the RF signal on switch on For more information see below Press the ON OFF button until OFF appears o...

Page 10: ...h to the left to the position MUTE The plug on transmitter reacts as indicated in the table Press the ON OFF button Locked appears on the display panel Press the UP button Unlock appears on the displa...

Page 11: ...Transmitter s display panel Transmission icon is displayed MUTE is not displayed You can also deactivate the RF signal on switch on For more infor mation refer to the chapter Switching the plug on tra...

Page 12: ...the frequency bank and the channel 13 Name Enters the transmitter name 14 Auto Lock Activates deactivates the automatic lock mode 14 Advanced Calls up the extended menu Advanced Menu 14 Exit Exits the...

Page 13: ...last selected menu item is displayed Press the UP button DOWN button to change to the Sensitivity menu item The current setting of the selected menu item is displayed Press the SET button to call up t...

Page 14: ...oo high Close talking distances speakers with loud voices or loud music passages cause overmodulation in the trans mission link The audio level display AF shows full deflection for the duration of the...

Page 15: ...use the lock mode refer to page 9 The extended menu Advanced Menu Setting transmission frequencies and the frequency bank U Tune When you have selected one of the system banks and then select the Tune...

Page 16: ...il the frequency bank selec tion appears Press the SET button The frequency selection appears Mode Function AF On Off When the switch is in the MUTE position no audio signal is transmitted RF On Off W...

Page 17: ...in 16 steps Loading the factory preset default settings Reset When resetting the plug on transmitter only the selected settings for the pilot tone and for the frequency bank U remain unchanged For an...

Page 18: ...ation on automatic synchronization of the plug on transmitter with the receiver individual operation refer to the instruction manual of the receiver This information is marked with the icon Alternativ...

Page 19: ...rge extent on location and can vary from about 10 m to about 150 m There should be a free line of sight between plug on transmitter and receiving antennas To avoid overloading the receiver observe a m...

Page 20: ...on trans mitter to the same channel as the receiver Synchronize the plug on transmitter with the receiver see page 17 Transmissionrange is exceeded Reduce the distance between plug on trans mitter and...

Page 21: ...0 Accessories Accessories The following SKP 100 G3 accessories are available from your specialist dealer Cat No Accessory 009950 BA 2015 accupack 009828 L 2015 charger 005232 POP 1 pouch with belt cli...

Page 22: ...an be switched off Compander system Sennheiser HDX AF frequency response 80 18 000 Hz Signal to noise ratio 1 mV RF peak deviation 110 dBA THD 0 9 Max input voltage 3 3 Vrms Input impedance 60 k unbal...

Page 23: ...e received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rule...

Page 24: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 01 09 529675 A01...

Reviews: