Specifications

Power supply and connections

Polar pattern and frequency response

Cleaning

125 Hz

250 Hz

500 Hz

1,000 Hz

2,000 Hz

4,000 Hz
8,000 Hz

16,000 Hz

30°

180°

150°

120°

60°

90°

0
5

10
15
20
25
dB

30°

180°

150°

120°

60°

90°

Effect of switchable roll-off-filter
Effect of switchable treble emphasis

-10 dB

1

1

3

3

2

2

super-cardioid/lobar
50 – 20,000 Hz
50 (15) mV/Pa ±1 dB

124 (132) dB / 1 kHz

5 (13) dB(A)

16 (24) dB
150 Ω
1 kΩ

48 V ±4 V
2 mA
⌀ 25 x 410 mm
approx. 180 g

Pick-up pattern
Frequency response
Sensitivity (free field, 

no load, 1 kHz)
Max. SPL
Equivalent noise level

     DIN IEC 651

     CCIR 468-3
Nominal impedance
Min. terminating 

impedance
Phantom powering
Current consumption
Dimension
Weight

Values in () with attenuator switched on (–10 dB)

20

10

0

-10

-20

-30

50

20

100

200

500

1,000

2,000

5,000

10,000

20,000

Hz

dB

6.8 k

6.8 k

48 V ± 4 V

or optional 

3.3 kΩ when 

using trans- 

formers with 

center tap

Phantom powering