18
Specifications
HME 26-600/-100
Headphones
Transducer principle
dynamic, closed
Ear coupling
supra-aural
Frequency response
20–18,000 Hz
Impedance
HME 26-600
300
Ω
mono/600
Ω
stereo
HME 26-600S
600
Ω
mono
HME 26-100
50
Ω
mono/100
Ω
stereo
Characteristic SPL
105 dB SPL at 1 kHz, 1 mW
HME 26-600/-600S
107 dB SPL at 1 kHz, 1 V
HME 26-100
115 dB SPL at 1 kHz, 1 V
(ActiveGard switched off)
Max. SPL
105 dB SPL at 1 kHz
(ActiveGard switched on)
HME 26-600/-600S
127 dB SPL at 1 kHz, 200 mW
HME 26-100
128 dB SPL at 1 kHz, 200 mW
(ActiveGard switched off)
THD
< 0.5 % at 1 kHz
Contact pressure
approx. 3.6 N
Microphone
Type
MD 424
Transducer principle
pre-polarized condenser
microphone, omni-directional
Frequency response
40–16,000 Hz
Output voltage
4 mV/Pa
±
2.5 dB
Terminating impedance
min. 4.7 k
Ω
Supply voltage
5–15 V DC
General data
Temperature range
operation: –15 °C to 55 °C
storage:
–55 °C to 70 °C
Weight without cable
HMD 26-600/-100
approx. 200 g
HMD 26-600S
approx. 130 g
Book_523984_1208_SP7.book Seite 18 Montag, 5. Januar 2009 10:09 10