background image

You can use the S-MCD to manage and control up to 126 EM 3532-U and EM 1046 
receivers. The EM 3532 receivers are coupled in series by means of data cables and 
are subsequentl y connected to the PC via an RS 485 interface — additional inter-
face modules are not required. The EM 1046 receivers are connected to the parallel 
interface of the PC via the EM 1046 DI display interface.  For detailed information 
of  the  installation  of  the  EM  1046  receivers,  please  refer  to  the  chapter  ”5000 
Series Receiver Systems“. 

Using  S-MCD  you  can  program  entire  sequences  of  scenes  with  several  actors 
without  having  to  change  the  transmitter/receiver  unit.  Each  actor  keeps  his  or 
her transmitter and can be switched in when necessary. During operation  you can 
monitor  battery  status,  volume  level,  and  transmission  frequency.  If  necessary, 
you can switch to another frequency.

The “Receiver  Configuration”  window  (see  fig.  3)  offers  about  the  same  displays 
and  menus  that  are  also  directl y  available  on  the  receiver.  The  “RF”  and  “Dev” 
bargraphs provide information on RF and AF levels. The “Batt” bargraph indicates 
the battery status.  With the “Squelch” control,  you can determine the  operating 
thresh old  for the RF squelch. The  frequency  list shows the  frequencies and their 
allocated channel numbers. 

By clicking the “Scan up” and “Scan down” buttons, the EM 3532‘s scan function is 
activated. If a frequency is found, it is displayed in the frequency list.

The  RF  recorder  menu  offers  two  operating  modes.  In  the  “RF  Level  Recorder” 
mode  you  can  record  measuring  values  over  a  certain  period  of  time.  In  the 
“RF Spectrum Anal yzer” mode (EM 3532 onl y) (see fig. 4)  you can record measu-
ring data of a defined frequency range.

EM 3532-U

RF Wireless Systems |

 3000 Series Receivers

EM 3532 back panel features

Fuse holder and mains voltage selector

Mains connector

Cable crip for mains cable

10  Data interface for connecting a remote computer

11  AF output XLR-3M, balanced
12  Control for the AF output level at the XLR socket
13  Antenna socket B
14  DC socket
15  Antenna socket A

7

8

9

10

11

12

13

14

10

11

12

15

Fig. 1: Display of a scene configuration with many 
actors on the  S-MCD Mikroport computer display

Fig. 2: Display of a scene configuration with four actors 
on the S-MCD Mikroport computer display

Fig. 3: Window “Receiver Configuration”

Fig. 4: Window “RF Recorder”, “RF Spectrum Analyzer”

Reviews: