background image

EKI 830

Printed in Germany, Publ. 05/12, 549106/A01

Am Labor 1, 30900 Wedemark, Germany
www.sennheiser.com

Sennheiser electronic GmbH & Co. KG

EKI 830

Infrared bodypack receiver

Instruction manual

Summary of Contents for EKI 830

Page 1: ...EKI 830 Printed in Germany Publ 05 12 549106 A01 Am Labor 1 30900 Wedemark Germany www sennheiser com Sennheiser electronic GmbH Co KG EKI 830 Infrared bodypack receiver Instruction manual ...

Page 2: ...EKI830 book Seite 1 Donnerstag 10 Mai 2012 2 02 14 ...

Page 3: ... 830 into operation 6 Removing and charging the rechargeable battery 6 Using the EKI 830 8 Connecting headphones or an induction coupler 8 Wearing the receiver 9 Cleaning and maintaining the EKI 830 11 If a problem occurs 12 Accessories 13 Specifications 14 Manufacturer Declarations 15 EKI830 book Seite 1 Donnerstag 10 Mai 2012 2 02 14 ...

Page 4: ...peratures hairdryer heater extended exposure to sunlight etc to avoid corrosion or deformation 왘 Only use attachments accessories supplied or recommended by Sennheiser 왘 Only clean the product with a soft dry cloth Intended use liability The receiver can be used together with infra red transmission systems which operate on a carrier frequency of 2 3 or 2 8 MHz Headphones with 3 5 mm jack plugs ind...

Page 5: ...using recharge able batteries for extended periods of time charge them regularly about every 3 months Store charged rechargeable batteries so that the terminals cannot contact each other danger of shorting out fire hazard Only charge rechargeable batteries at ambient temperatures between 10 C 50 F and 40 C 104 F Do not mutilate or dismantle Do not continue to use defective rechargeable batteries a...

Page 6: ...an induction loop Areas of application The EKI 830 receiver can be used together with infra red transmission systems which operate on a carrier frequency of 2 3 or 2 8 MHz exam ple Sennheiser SZI SI 1015 Alternatively the receiver can be used with transmitters of the Sennheiser Set 830 S Set 830 TV and Set 900 infra red hearing systems SI 1015 SZI 1015 EKI 830 HDI 830 EKI830 book Seite 4 Donnersta...

Page 7: ...anual 1 quick start guide for display at the receiver counter Product overview 1 Channel indicator 2 Volume control 3 On off button 4 Balance control 5 Channel selection button 6 Battery compartment 7 Socket for headphones induction loop or connec tion cable to hearing aid 1 3 4 7 5 7 6 2 EKI830 book Seite 5 Donnerstag 10 Mai 2012 2 02 14 ...

Page 8: ...ation on charging refer to the instruction manual of the L 300 10 10 or to the instruction manual of the corresponding Sennheiser infra red hearing system Charging the rechargeable battery separately When a rechargeable battery is discharged you can use the receiver with an optional spare rechargeable battery 왘 Remove the discharged battery from the receiver and recharge the battery in the L 300 1...

Page 9: ...s the on off button The receiver switches on the LEDs light up If the correct channel is already set no further steps are necessary To select a different channel 왘 Press the channel selection button repeatedly until the channel indi cator displays the desired channel see table If no further buttons are pressed the channel indicator goes off after 30 seconds If no channel is found the channel indic...

Page 10: ...11 induction loop or the EZI 120 induction plates or a connection cable with 3 5 mm jack plug to your hearing aid Connecting headphones 왘 Connect the 3 5 mm jack plug of the headphones to the socket of the receiver Connecting the induction loop 왘 Carefully remove the clip from the receiver 왘 Attach the clip of the induction loop as shown 왘 Connect the 3 5 mm jack plug of the induction loop to the ...

Page 11: ...nyard Attaching the receiver to clothing using the clip For alternative connection possibilities to your hearing aid as well as the connection to cochlea implants please contact your hear ing aid acoustician 왘 Connect the fasteners of the lanyard to the metal ring at the rear of the receiver 왘 Wear the receiver around your neck with the Sennheiser logo facing away from your body 왘 Attach the clip ...

Page 12: ... the on off button until the channel indicator lights up If no further buttons are pressed the chan nel indicator goes off after 30 seconds To switch the receiver off 왘 Press the on off button until the channel indicator lights up briefly and then goes off 왘 Use the volume control to adjust the vol ume to a sufficient and comfortable level The balance control allows for right left vol ume adjustme...

Page 13: ...to clean the product CAUTION Liquids can damage the electronics of the product Liquids entering the housing of the product can cause a short circuit and damage the electronics 왘 Keep all liquids far away from the product 왘 Do not use any cleansing agents or solvents EKI830 book Seite 11 Donnerstag 10 Mai 2012 2 02 14 ...

Page 14: ...e volume control see page 10 The rechargeable battery is not inserted properly into the receiver Remove the rechargeable battery and reinsert it into the receiver s battery compartment see page 6 The rechargeable battery is flat Recharge the rechargeable battery see page 6 The receiver is outside the transmission range Move the receiver closer to the transmitter The transmission system and the rec...

Page 15: ...at No Accessory Sennheiser headphones 002146 HD 410 003985 HD 1029 502861 PX 90 004917 PMX 60 502860 PMX 90 005225 GP 03 Cat No Sennheiser accessory for your hearing aid 502566 EZT 3011 induction loop 003448 EZI 120 induction plates Cat No Accessory 502710 L 300 10 10 charger 500898 BA 300 spare rechargeable battery 528185 Lanyard 528184 Clip EKI830 book Seite 13 Donnerstag 10 Mai 2012 2 02 14 ...

Page 16: ...n typ 75 dBA THD 1 Operating time up to 12 hrs Charging time for rechargeable battery approx 3 hrs Power supply BA 300 Lithium Polymer rechargeable battery 3 7 V 150 mAh Weight approx 50 g with rechargeable battery Dimensions approx 70 x 60 x 25 mm Europe EMC EN 55013 EN 55020 EN 60065 USA 47CFR15_B Safety UL 2054 Canada IC ICES 003 EKI830 book Seite 14 Donnerstag 10 Mai 2012 2 02 14 ...

Page 17: ...oHS Directive 2002 95 EC Battery Directive 2006 66 EC The supplied rechargeable batteries can be recycled Please dispose of them as special waste or return them to your specialist dealer In order to protect the environment only dispose of exhausted batteries CE Declaration of Conformity EMC Directive 2004 108 EC The declaration is available at www sennheiser com Before putting the product into ope...

Page 18: ...16 EKI 830 Manufacturer Declarations EKI830 book Seite 16 Donnerstag 10 Mai 2012 2 02 14 ...

Page 19: ......

Page 20: ...06 A01 Am Labor 1 30900 Wedemark Germany www sennheiser com Sennheiser electronic GmbH Co KG EKI 830 Infrared bodypack receiver Bedienungsanleitung Instruction manual Notice d emploi Istruzioni per l uso Instrucciones de uso Gebruiksaanwijzing ...

Reviews: