![Sennetech SCT-1041 Manual Download Page 4](http://html1.mh-extra.com/html/sennetech/sct-1041/sct-1041_manual_1239830004.webp)
4
High Address
Low Address
U11
U10
U9
U8
U13
U7
U6
U3
U5
U4
CN7
CN6
CN5
CN4
CN3
CN2
CN1
U2
U1
SW4
SW3
SW1
SW2
SENNETECH
55-9702
1 2 3 4
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
On
Off
Off
On
Off
On
1 2 3
SW4-1
VICON CONTROLLER
ON: VARIABLE SPEED
OFF: FIXED SPEED
The preferred method of operation is simplex mode, with only the Vicon cmd data line connected.
If the Vicon response line is connected for duplex operation, the code translator will appear as a
group of cameras to the controller. To prevent interference between the responses from the code
translator and any Vicon cameras in the system, set the switches to exclude any Vicon camera
addresses.
Note: If the Vicon control system is operating in simplex mode and does not require the response
line, the address switches can be set to the maximum range.
SETTING THE SWITCHES
To set the configuration switches, remove the back panel, which is secured by two screws. Then
slide the cover back to expose the switches. The switches can be changed while the code trans-
lator is powered up and the new settings will take effect immediately.
SW3-1
GLOBAL IRIS COMMANDS
ON: ENABLED
OFF: DISABLED
This switch is ignored if SW3-4 is ON.
Some Diamond receivers require the auto
iris status bits to be sent continuously along
with the pan, tilt, zoom, and focus. If this
switch is ON, the operator can change the
global setting for the code translator.
When auto iris is set to Global On, the auto
iris bits will be sent to each camera as it is
being controlled. An individual camera ad-
dress can be set to the opposite of the global
setting.
SW3-2
GLOBAL IRIS DEFAULT
ON: AUTO IRIS
OFF: MANUAL IRIS
Sets the default state for the iris commands
on power-up
SW3-4
KD6 OPERATION
ON: MAXPRO MODE
OFF: NORMAL MODE
Set to ON if connecting to KD6 domes con-
figured for operation with a Maxpro control-
ler (This is the preferred setup.)
Set to match the lowest
camera address to which
the code translator will
respond
Set to match the highest
camera address to which
the code translator will
respond
Summary of Contents for SCT-1041