background image

 

SMART CLEANER  

USER’S MANUAL 

 

 

4.

 

Cleaning Method 

The Smart Cleaner has two positions, “CLEAN”, and “LOCK”. 
Use the “LOCK” position when replacing the cartridge. 
Switch between  “LOCK” and “CLEAN” by holding the guide 
lock and rotating the slider until it reaches the proper 
positions. When cleaning, match the “

“ mark on the body 

to the “

CLEAN” mark on the slider.  

 

 
1) Optical Connector Ferrule Inside an Optical Adapter      (2) Optical Connector Ferrule (no adapter) 
 

 

 

 

 

 

 

First, place the attachment on the guide tip.

 

 Insert until the guide tip 

touches inside the optical 
adapter and then push the 
slider. The cleaning string is 
advanced and the cleaner 
rotates, cleaning the optical 
connector ferrule. 

 

 

 Remove the cap from the end of 

the attachment and insert the 
connector into the tip hole. Hold the 
connector firmly in your hand and in 
this fixed position push in the slider. 
The cleaning string is advanced and 
the cleaner rotates, cleaning the 
optical connector ferrule.

 

 

 

Cleaning ends when the 

slider is pushed all the way. 
When pressure is relieved the 
slider naturally returns to its 
starting position, ready for the 
next cleaning. Pull out the 
cleaner from the adapter to end 
the cleaning process.

 

 

 

 

Cleaning ends when the slider is 

pushed all the way. When pressure 
is relieved the slider naturally 
returns to its starting position, 
ready for the next cleaning. Pull 
out the cleaner from the adapter 
to end the cleaning process.

 

 

5.

 

Replacing the Cartridge 

When replacing the cartridge, move the “

 “ mark on the body to match the “

 LOCK” mark on the slider. 

(1) Removing the Cartridge 

 

 

                (2) Attaching the Cartridge 

 

First, remove the attachment 
from the guide, and store it in 
the attachment hole on the 
handle. Holding the slider and 
the guide lock in both hands pull 
them straight apart from both 
sides. Take care not to bend or 
twist the guide lock or slider 
while pulling them apart

 

 

 
*When changing the cartridge without 
removing the attachment from the guide, the 
cap of the attachment could break.

 

 

 

Match the convex part of the 

cartridge to the concave part of the 
body and push the slider and the guide 
lock straight in. 

 

 

 

 

Confirm that the convex part of the 

cartridge is locked into the concave 
part of the slider body to complete the 
cartridge attachment.

 

 

*The standard for replacing cartridges is 3 times per Retaining Handle. 
* The retainer handle is designed specifically for either MU, LC use or SC, FC, ST, E-2000 use. Please confirm for either MU, LC use or SC, FC, ST, E-2000 use 
when purchasing replacement cartridges. 
 

 

 

 

 

 

 

           

 

 

           

 

     

 

 

Senko Advanced Components, Inc. 

 

 

                      www.senko.com/smartcleaner 

Produced by NTT-AT 

 

Americas 

 

Asia

 

Europe

 

Asia Pacific                                      

 

Japan 

USA EAST  +1-888-32-SENKO 

HONG KONG +852-2121-0516                   

UK +44 (0) 1256 700880                   

AUSTRALIA  

TOKYO  

USA WEST +1-858-623-3300 

SH86-21-5830-4513                  

ITALY +39 011 839 9828                    

+61 (0) 3 9755-7922       

+81 (0)3 5825-0911

 

TEXAS 1-972-661-9080 

SHENZHEN  

48-71 345-90-05 

[email protected]                       

[email protected] 

[email protected]                       

+86-755-2533-4893               

[email protected]                 

 

Middle East - North Africa

 

BRAZIL: +55-21-3736-7065

 

[email protected]

 

[email protected]                                  

 

 

DUBAI +971 4 8865160 
[email protected]                                  

 

Reviews: