SMART CLEANER
USER’S MANUAL
4.
Cleaning Method
The Smart Cleaner has two positions, “CLEAN”, and “LOCK”.
Use the “LOCK” position when replacing the cartridge.
Switch between “LOCK” and “CLEAN” by holding the guide
lock and rotating the slider until it reaches the proper
positions. When cleaning, match the “
“ mark on the body
to the “
CLEAN” mark on the slider.
1) Optical Connector Ferrule Inside an Optical Adapter (2) Optical Connector Ferrule (no adapter)
First, place the attachment on the guide tip.
①
Insert until the guide tip
touches inside the optical
adapter and then push the
slider. The cleaning string is
advanced and the cleaner
rotates, cleaning the optical
connector ferrule.
①
Remove the cap from the end of
the attachment and insert the
connector into the tip hole. Hold the
connector firmly in your hand and in
this fixed position push in the slider.
The cleaning string is advanced and
the cleaner rotates, cleaning the
optical connector ferrule.
②
Cleaning ends when the
slider is pushed all the way.
When pressure is relieved the
slider naturally returns to its
starting position, ready for the
next cleaning. Pull out the
cleaner from the adapter to end
the cleaning process.
②
Cleaning ends when the slider is
pushed all the way. When pressure
is relieved the slider naturally
returns to its starting position,
ready for the next cleaning. Pull
out the cleaner from the adapter
to end the cleaning process.
5.
Replacing the Cartridge
When replacing the cartridge, move the “
“ mark on the body to match the “
LOCK” mark on the slider.
(1) Removing the Cartridge
(2) Attaching the Cartridge
First, remove the attachment
from the guide, and store it in
the attachment hole on the
handle. Holding the slider and
the guide lock in both hands pull
them straight apart from both
sides. Take care not to bend or
twist the guide lock or slider
while pulling them apart
.
*When changing the cartridge without
removing the attachment from the guide, the
cap of the attachment could break.
①
Match the convex part of the
cartridge to the concave part of the
body and push the slider and the guide
lock straight in.
②
Confirm that the convex part of the
cartridge is locked into the concave
part of the slider body to complete the
cartridge attachment.
*The standard for replacing cartridges is 3 times per Retaining Handle.
* The retainer handle is designed specifically for either MU, LC use or SC, FC, ST, E-2000 use. Please confirm for either MU, LC use or SC, FC, ST, E-2000 use
when purchasing replacement cartridges.
Senko Advanced Components, Inc.
www.senko.com/smartcleaner
Produced by NTT-AT
Americas
Asia
Europe
Asia Pacific
Japan
USA EAST +1-888-32-SENKO
HONG KONG +852-2121-0516
UK +44 (0) 1256 700880
AUSTRALIA
TOKYO
USA WEST +1-858-623-3300
SH86-21-5830-4513
ITALY +39 011 839 9828
+61 (0) 3 9755-7922
+81 (0)3 5825-0911
TEXAS 1-972-661-9080
SHENZHEN
48-71 345-90-05
+86-755-2533-4893
Middle East - North Africa
BRAZIL: +55-21-3736-7065
DUBAI +971 4 8865160
[email protected]